WARNING: Before Operating Your Unit

WARNING

Electrical Shock Hazard

Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.

Do not use plug adapters.

Do not use an extension cord.

Do not remove ground prong.

Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.

Make sure the wiring is adequate for your unit.

If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1.

DO NOT use an extension cord.

The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not.

Make sure that the receptacle is compatible with the air conditioner cord plug provided.

Proper grounding must be maintained at all times. Two prong receptacles

The grounded receptacle should meet all national and local codes and ordinances. You must use the three prong plug furnished with the air conditioner. Under no circumstances should you remove the ground prong from the plug.

NOTICE

Do not use the LCDI device as an ON/OFF switch.

Failure to adhere to this precaution may cause premature equipment malfunction.

Once plugged in, the unit will operate normally without the need to reset the LCDI device. If the LCDI device fails to trip when tested or if the power supply cord is damaged, it must be replaced with a new power supply cord from the manufacturer. Contact our Technical Assistance Line at (800) 541-6645. To expedite service, please have your model number available.

Table 1.

 

CIRCUIT RATING

REQUIRED

 

OR TIME DELAY

WALL

MODEL

FUSE

RECEPTACLE

 

 

 

 

 

 

 

 

 

 

 

 

 

AMP

VOLT

NEMA

 

 

 

 

 

 

 

 

 

 

NO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS08M10, SS10M10,

 

 

 

 

 

 

 

 

 

 

 

 

SS12M10, SS14M10,

15

125

5-15R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YS10M10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS12M30, SS15M30,

15

250

6-15R

 

 

 

 

 

 

 

 

 

SM18M30, SM21M30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM24M30, SL28M30,

 

 

 

 

 

 

 

 

 

 

 

 

ES12M33, ES15M33,

20

250

6-20R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YS12M33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SL36M30, EM18M34,

 

 

 

 

 

 

 

 

 

 

 

 

EM24M34, EL36M35,

30

250

6-30R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YM18M34, YL24M35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test the power cord

All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device on the end of the cord meets the UL and NEC requirements for cord connected air conditioners.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET (See Figure 1).

3.Press TEST, listen for click; the RESET button trips and pops out.

4.Press and release RESET (Listen for click; RESET button latches and remains in). The power cord is ready for use.

Figure 1

RESET

TEST

WARNING

TEST BEFORE EACH USE

1.PRESS RESET BUTTON

2.PLUG LCDI INTO POWER RECEPTACLE

3.PRESS TEST BUTTON,

RESET BUTTON SHOULD

POP UP

4.PRESS TEST BUTTON, FOR USE

DO NOT USE IF ABOVE TEST

FAILS

WHEN GREEN LIGHT IS ON

IT IS WORKING PROPERLY

TEST

RESET

WARNING

TEST BEFORE EACH USE

1.PRESS RESET BUTTON

2.PLUG LCDI INTO POWER RECEPTACLE

3.PRESS TEST BUTTON, RESET BUTTON SHOULD POP UP

4.PRESS TEST BUTTON, FOR USE

DO NOT USE IF ABOVE TEST FAILS

WHEN GREEN LIGHT IS ON IT IS WORKING PROPERLY

15/20A LCDI Device

30A LCDI Device

FRR001

6

Page 6
Image 6
Friedrich SL28M30, SS14M10, SS12M30, SS15M30, SS10M10, SS12M10, SS08M10, SM24M30 Make sure the wiring is adequate for your unit

SM18M30, SS08M10, SM24M30, SS14M10, SS12M10 specifications

Friedrich's SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 are a series of high-performance mini-split air conditioners that cater to various residential and commercial needs. Designed with efficiency and user comfort in mind, each model displays advanced technologies, appealing features, and distinct characteristics.

The SS12M30 and SS10M10 units are part of Friedrich's top-tier Mini-Split line, known for their high SEER ratings, which signifies energy efficiency. The SS12M30 boasts a cooling capacity of 12,000 BTUs, making it suitable for medium-sized rooms. Its inverter-driven compressor adjusts the cooling output in real time, allowing for quieter operation and lower energy consumption. The SS10M10, on the other hand, has a slightly lower cooling capacity of 10,000 BTUs, ideal for smaller spaces, ensuring the same energy-efficient operation and quiet performance.

The SL36M30 model stands out with a notable feature set focused on providing further energy savings and enhanced comfort. With a cooling capacity of 36,000 BTUs, it is designed for larger areas, such as open-concept living spaces or commercial environments. This model features a built-in Wi-Fi capability, allowing users to control their cooling preferences remotely via smartphone applications. Such connectivity not only enhances user convenience but also helps in monitoring energy usage effectively.

The SS15M30 offers a strong performance with its 15,000 BTU output. Its design incorporates advanced filtration systems, improving indoor air quality by capturing airborne allergens, dust, and pollutants. This model is also equipped with a silent operation mode, ensuring that comfort is maintained without intrusive noise.

Lastly, the SL28M30 delivers a balanced combination of power and efficiency. With a focus on sustainability, this unit includes eco-friendly refrigerants and complies with stringent environmental regulations. The SL28M30 also features user-friendly programmable settings that allow for precision in temperature management, adapting seamlessly to users' lifestyle patterns.

In summary, Friedrich’s SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 models provide versatile cooling solutions suitable for various spaces. With a focus on efficiency, user comfort, connectivity, and air quality, these air conditioners represent a significant advancement in HVAC technology, perfect for meeting today's demands for both residential and commercial applications. Each model combines cutting-edge features and reliable performance, making them exceptional choices for consumers looking to enhance their indoor climate control.