Routine Maintenance

monthly, and more frequently if conditions warrant. The unit must be turned

WARNING

ELECTRICAL SHOCK HAZARD

Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.

Do not use plug adapters.

Do not use an extension cord.

Do not remove ground prong.

Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.

To Remove, Wash and Replace Filter

Coils & Chassis

NOTE: Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser. The use of harsh cleaning materials may lead to deterioration of the

The indoor coil and outdoor coils and base pan should be inspected periodically (annually or semi-annually) and cleaned of all debris (lint, dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more frequent cleaning may be required. Clean the coils and base pan with a soft brush and compressed air or vacuum. A pressure washer may also be used,

pack when pressure cleaning coils.

NOTE: It is extremely important to insure that none of the electrical and/or electronic parts of the unit get wet. Be sure to cover all electrical components to protect them from water or spray.

Decorative Front

Use a damp (not wet) cloth when cleaning the control area to prevent water from entering the unit, and possibly damaging the electronic control.

The decorative front and the cabinet can be cleaned with warm water and a mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners such as acetone, naphtha, gasoline, benzene, etc.

The indoor coil can be vacuumed with a dusting attachment if it appears to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed with a hose if you can get to it. If not, you might call your dealer for a more thorough cleaning when needed.

vacuuming with a dust attachment or by cleaning in the sink using warm

reinstalling. Use caution the coil surface can be sharp.

Fan Motor & Compressor

The fan motor & compressor are permanently lubricated, and require no additional lubrication.

Wall Sleeve

Inspect the inside of the wall sleeve and drain system periodically (annually or semi-annually) and clean as required. Under extreme conditions, more frequent cleaning may be necessary. Clean both of these areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as needed.

Service and Assistance

Before calling for service, please check the “Troubleshooting Tips” section

avoid unnecessary service calls, and save you the cost of a service call if the problem is not due to the product itself. If you have checked the “Basic Troubleshooting” section and still need help, it is available as follows:

our web site at www.friedrich.com.

If you require further assistance

You can call the Customer Support Call Center at 1-800-541-6645.

Before calling, please make sure that you have the complete model and serial number, and date of purchase of your equipment available. By providing us with this information, we will be better able to assist you.

Our specialists are able to assist you with:

υ

υReferrals to dealers, and distributors.

υUse and Care Information.

υRecommended maintenance procedures.

υInstallation information.

υReferrals to Authorized Service Providers and Parts depots.

Available Accessories

DC-2 Drain Kit – Part No. 01900235

In some installations, excess condensate water caused by extremely humid conditions, may result in an undesirable water drip such as on a patio or over an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be installed to drain excess condensation to an alternate location.

Carbon Filter Kits

The kits vary depending on the chassis size (small, medium, large). Each

WCFS

WCFM

WCFL

Remote Wall Thermostats

RT4 – Digital wall thermostat hard wired with single speed fan.

RT5 – Digital wall thermostat hard wired with two fan speed selection, battery backup and backlight display.

Window Installation Kits (Standard in Kühl Models without Heat)

KWIKS – For all ES and YS models.

KWIKM – For all EM and YM models.

KWIKL – For all EL and YL models.

See www.friedrich.com for additional accessories for your unit.

39

Page 39
Image 39
Friedrich ES15M33, SS14M10, SS12M30, SS15M30, SS10M10, SS12M10, SS08M10, SL28M30, SM24M30, SL36M30, SM18M30 Routine Maintenance

SM18M30, SS08M10, SM24M30, SS14M10, SS12M10 specifications

Friedrich's SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 are a series of high-performance mini-split air conditioners that cater to various residential and commercial needs. Designed with efficiency and user comfort in mind, each model displays advanced technologies, appealing features, and distinct characteristics.

The SS12M30 and SS10M10 units are part of Friedrich's top-tier Mini-Split line, known for their high SEER ratings, which signifies energy efficiency. The SS12M30 boasts a cooling capacity of 12,000 BTUs, making it suitable for medium-sized rooms. Its inverter-driven compressor adjusts the cooling output in real time, allowing for quieter operation and lower energy consumption. The SS10M10, on the other hand, has a slightly lower cooling capacity of 10,000 BTUs, ideal for smaller spaces, ensuring the same energy-efficient operation and quiet performance.

The SL36M30 model stands out with a notable feature set focused on providing further energy savings and enhanced comfort. With a cooling capacity of 36,000 BTUs, it is designed for larger areas, such as open-concept living spaces or commercial environments. This model features a built-in Wi-Fi capability, allowing users to control their cooling preferences remotely via smartphone applications. Such connectivity not only enhances user convenience but also helps in monitoring energy usage effectively.

The SS15M30 offers a strong performance with its 15,000 BTU output. Its design incorporates advanced filtration systems, improving indoor air quality by capturing airborne allergens, dust, and pollutants. This model is also equipped with a silent operation mode, ensuring that comfort is maintained without intrusive noise.

Lastly, the SL28M30 delivers a balanced combination of power and efficiency. With a focus on sustainability, this unit includes eco-friendly refrigerants and complies with stringent environmental regulations. The SL28M30 also features user-friendly programmable settings that allow for precision in temperature management, adapting seamlessly to users' lifestyle patterns.

In summary, Friedrich’s SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 models provide versatile cooling solutions suitable for various spaces. With a focus on efficiency, user comfort, connectivity, and air quality, these air conditioners represent a significant advancement in HVAC technology, perfect for meeting today's demands for both residential and commercial applications. Each model combines cutting-edge features and reliable performance, making them exceptional choices for consumers looking to enhance their indoor climate control.