If the system mode is set to AUTO (Heat-Cool Unit only), a 2nd temperature

labeled “Heat !! Set Point” displays. Use (UP) or (DOWN) arrows to increment/decrement the heat temperature. The other parameters (SYSTEM, FAN SPEED, FAN MODE) cannot be changed on this screen. The temperature range for AUTO mode must remain a minimum of 3 degrees apart at all times. If the high or low temperature is adjusted too close to its counterpart, that temperature not being directly changed will increase/decrease as needed to maintain the 3 degree spread. The user

presses to advance to the next time period.

FRR039

If the user selects FAN-Only mode, the word FAN displays for 2 seconds. In this mode you may adjust the FAN SPEED. The FAN SPEED options are: LOW, MED, HIGH or MAX*. Fan speed depends on your unit's model. The MAX* Setting is available on all SS and SM models.

FRR040

If the user wants the air conditioner to power down for a period of time, pressing hibernation until the next scheduled period. This feature is available during

FRR041

If the user should decide they don’t want to use any or all four time

periods for the day, they can set any period to be pressing This will blank out the options and display the word SKIP. This can be undone by

pressing again. The digital control defaults to the time period setting

inmediately prior to the user advancing to SKIP. Press , to continue continue on to the next time period. SKIP continues the settings of the previous time period, it will terminate at the start of the next time period where SKIP is not selected.

Set Schedule – Away, Return, Night Periods

FRR042

Each of the additional periods (Away, Return, Night) are programmed identical to the programming for the Wake period. The appropriate

sequence.

Once the user has programmed all four (4) time periods, the program goes to the next day or day group by pressing SCHEDULE. For example, if individual days are being programmed, the program will go from Mon to Tues leading the user through 4 periods for Tues until it reaches the end of the week.

NOTE: Day group sequence is as follows: Monday through Friday (weekday), Saturday – Sunday (weekend), Monday through Sunday (7-day), and individual days Mon !!Tue !!Wed !!Thru

!! !! !!

Note that by pressing SCHEDULE repeatedly the process follows a continuous loop until the user decides to exit.

When the user has completed setting start times and options (or at any

point in the process) they can press

 

toggle to the next day (or set of

days), or they can press and hold for 3 seconds to save their changes and exit the set schedule mode. Once programmed you can SAVE and EXIT or select another day group by pressing SCHEDULE.

Schedule Mode Completed.

FRR043

 

37

Page 37
Image 37
Friedrich SM18M30, SS14M10, SS12M30, SS15M30, SS10M10, SS12M10, SS08M10, SL28M30 Set Schedule Away, Return, Night Periods

SM18M30, SS08M10, SM24M30, SS14M10, SS12M10 specifications

Friedrich's SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 are a series of high-performance mini-split air conditioners that cater to various residential and commercial needs. Designed with efficiency and user comfort in mind, each model displays advanced technologies, appealing features, and distinct characteristics.

The SS12M30 and SS10M10 units are part of Friedrich's top-tier Mini-Split line, known for their high SEER ratings, which signifies energy efficiency. The SS12M30 boasts a cooling capacity of 12,000 BTUs, making it suitable for medium-sized rooms. Its inverter-driven compressor adjusts the cooling output in real time, allowing for quieter operation and lower energy consumption. The SS10M10, on the other hand, has a slightly lower cooling capacity of 10,000 BTUs, ideal for smaller spaces, ensuring the same energy-efficient operation and quiet performance.

The SL36M30 model stands out with a notable feature set focused on providing further energy savings and enhanced comfort. With a cooling capacity of 36,000 BTUs, it is designed for larger areas, such as open-concept living spaces or commercial environments. This model features a built-in Wi-Fi capability, allowing users to control their cooling preferences remotely via smartphone applications. Such connectivity not only enhances user convenience but also helps in monitoring energy usage effectively.

The SS15M30 offers a strong performance with its 15,000 BTU output. Its design incorporates advanced filtration systems, improving indoor air quality by capturing airborne allergens, dust, and pollutants. This model is also equipped with a silent operation mode, ensuring that comfort is maintained without intrusive noise.

Lastly, the SL28M30 delivers a balanced combination of power and efficiency. With a focus on sustainability, this unit includes eco-friendly refrigerants and complies with stringent environmental regulations. The SL28M30 also features user-friendly programmable settings that allow for precision in temperature management, adapting seamlessly to users' lifestyle patterns.

In summary, Friedrich’s SS12M30, SS10M10, SL36M30, SS15M30, and SL28M30 models provide versatile cooling solutions suitable for various spaces. With a focus on efficiency, user comfort, connectivity, and air quality, these air conditioners represent a significant advancement in HVAC technology, perfect for meeting today's demands for both residential and commercial applications. Each model combines cutting-edge features and reliable performance, making them exceptional choices for consumers looking to enhance their indoor climate control.