Better Light 7 manual Auto-rotate Retrieved Files, Mask

Page 80
Macintosh Appearance preferences.

Note that if the name for a saved prescan remains unchanged after a previous prescan with that name already being displayed in Photoshop, the new prescan data will overwrite the existing image file, but Photoshop will issue a warning that the (new) file is already open (since its name is the same as the file already being displayed), and will allow you to open a second window for the (already displayed) image; choosing to open a second window will NOT display the new image data, but instead will display a second copy of the older prescan data. For proper automatic viewing, it is necessary to either close or rename any preview image already open in Photoshop, or rename the new prescan when saving it.

The choice of the application to use for opening the files is made by clicking on the Choose Appli- cation… button. A standard file open dialog box will be presented. Navigate to the desired applica- tion (often this application is Photoshop), highlight the application and click the Open button. The name of the chosen application will then appear above the Choose Application… button.

Auto-rotate Retrieved Files

Checking the Auto-rotate retrieved files box will set an option in the saved TIFF image files that will signal Photoshop to rotate the image to the correct viewing orientation. This option only works with Photoshop CS2, or later. Earlier versions will ignore this option.

Mask

Adjustments for the color and transparency for the Crop Mask tool are located in the Preferences section marked Mask (Windows) or Appearance (Macintosh). When the Color button is clicked, the System Color Picker window is presented. Select the desired color and click on the OK button to set the mask color. If the main control window is visible and a crop mask is in effect, the window will update to show the new color when you click the OK button on the color picker window.

The transparency of the crop mask is controlled with the slider to the right of the Color button (Windows) or by the Color Picker trans- parency slider (Macintosh). By default, the slider is set to make the mask 50% transparent (in the center of the slider). The mask will be 100% transparent, and therefore it will not be visible, when the slider is at the far left. A totally opaque mask occurs when the slider is at the

extreme right. The mask can be adjusted to any intermediate value by moving the slider until the desired transparency is achieved. Changes to the transparency can be viewed interactively by selecting a cropped region and activating the crop mask before entering the Preferences window.

80

Image 80
Contents Large Format Digital Scanning Camera System Revision D MarchAcknowledgements Page Page Contents Lock Crop Ratio Locking BothAudio Focusing Aid Multiple Color Focusing Altering Color Balance for Mood or EffectSaving a High Bit Depth Image Limit LineExporting Notes Automatically Opening the ImageLighting Hardware Setup Software OperationLine Time Parts List Connector Identification Installing and Configuring the ViewFinder Software Getting StartedMemory Requirements System RequirementsMacintosh PC PC version of the software is requiredQuick Start Guide Connect the camera insert to the control unitConnect the control unit to the host computer Mate the female end of the cable with the DBConnect the AC power to the control unit Install the viewing overlay on the camera’s ground glassTurn on the digital camera Turn on the host computerInstall the infrared blocking filter Mm thick Tungsten infrared blocking filterSelect the image capture settings Compose and focus the imagePut the insert into the camera Start the ViewFinder softwarePrescan Take the pictureTransfer the file to the computer View the final imagePrescanning Making a PrescanFast Prescans Cropped Prescans Super View Prescans Color Managed Prescans Canceling a PrescanSaving and Viewing Prescans Rulers GuidesImage Capture Settings ResolutionPage Line Time ISO Capture Mode Exposure LockScanning to the Camera Disk Canceling a ScanScanning Naming the Image Automatically Naming ImagesAdding Notes to Your Picture RGB Data Values, EV Units Exposure EvaluationDigital Spot Metering Determining Relative Exposure Static Spot Meter Tool Setting the Spot Meter Size Histogram Judging Overall and Spot ExposuresStatic Spot Meter Location Readings Hand Tool Tool BarMagnify Tool Measure Tool Mac only Panorama ToolToneZones Tool Page Crop Mask Tool Grid ToolPage Scan Area & Cropping Tab PanelsSize Panel Size of the cropped area may still be adjusted while Different unit. Example 15.24 cm x 10.16 cm at 300 pixels perLock Crop Ratio To set a specific shape for crop rectangle Clicking up or down buttons of Scan AreaLock File Size To specify an exact file size Faster Scans for Free Seconds Scan directionColor Panel Establishing Neutral Color BalanceSaving Color Balances Altering Color Balance for Mood or Effect Changing Existing Color BalancesDeleting Color Balances Reverting to a Previous Color Balance Tagging Images with ICC ProfilesTone Panel Tone Curve SelectionsSaving a High Bit Depth Image Brightness/Contrast Tone Curve Adjustments Manual Tone Curve Adjustments Limit Line Spot Meter Reference PointsNegative Curves Bit Tone CurvesSelecting an Output Tone Scale Setting the EV Scale ReferenceTone Curve Histogram Saving Tone Curves Deleting Tone CurvesFocus Panel Large Focus DisplaySelecting a Focus Site Reading the Focus Displays and Adjusting Focus Audio Focusing Aid Mac only Multiple Color FocusingInfrared Focus Image File Management and Retrieval ViewFinder File Manager Exporting Notes Sorting Image FilesAdding more Notes to Your Pictures Automatically Saving Files to a Folder Automatically Opening the ImageRetrieving Image Files Selecting the Retrieval Tone Curve USB controller only Deleting Image Files Hard Drive Storage CapacityMenus File MenuEdit Menu Display Menu Camera Menu Capture Mode Clean/Park Diagnostics Opens the Clean/Park window to expose the CCD for cleaningUser Preferences Automatically Retrieving Images Saving FilesAfter highlighting the desired folder, click Right of the Save scan folder labelAutomatic Scan Viewing in an Application Auto File Open Automatically Save PrescansAuto Naming Auto-rotate Retrieved Files MaskGrid GuidesISO Increment Selection Using SoundsBaseline ISO Setting Pano Settings Use this feature, the factory settings are adequateTime Lapse CropCleaning the CCD Cover Glass Appendix aExposure Adjustments Appendix BManipulating Exposure Line TimeLens Aperture Color Balance SensitivityTone Curves Lighting Line Time Settings Appendix CResolution Selections Appendix DModel 4000E-HS Model 6000-HS, 6000E-HSSuper 6K-HS Super 8K-HS Status Indicators PowerAppendix E StatusHardware Setup Appendix FPanoramic Adapter Scene PanoramaPage Rollout Panorama Object Panorama Hardware is assembled just as it is for a Rollout panoramaError Messages Camera reported error Not ReadyCamera reported error No Room Camera reported error Conversion ErrorCamera reported error Value Error Camera reported error Math ErrorScsi Errors Comm returned error Other Errors Unknown ErrorCamera Timed Out