•Verify that proper lighting exists and that the camera shutter is open and allowing sufficient light into lens.
•Verify that exposure time is not too short.
•Verify camera is in
•Verify that all “enable” lines are connected for the camera. For example, some cameras have a line called “Control line” which needs to be set to the CRTL0 in order for the camera to function. The Control Lines can be set either “HIGH” or “LOW” in the PXD configuration application under “Exposure Timing”.
•Image depth or image dimensions may be incorrect. Verify that camera is configured properly for pixel type, (i.e. 8, 10 12 bit, 32bit RGB etc..), and verify that image dimensions are set correctly, (i.e. 1000x1000 2000x2000, etc..)
Symptom:
•Receiving ERR_CORRUPT message in the PXD Configuration Application.
Possible Cause/Solution:
•This error message is a very
Symptom:
•Changing gray image or changing image present but indistinguishable or jumbled.
Possible Cause/Solution:
•Data lines wired incorrectly. Verify that on the PXD1000, the data lines coming from the camera are biased to the higher order bits (see example in this manual). For example, if a
•Camera channel selection.. For example, if a
•Verify that pixels
•Incorrect Pixel ordering scheme. If the pixel order sent out from the camera is 2- ch,
•Any combination of the above. It is possible that the any of the above configuration issue may be present. Verify all configurations with the PXD Configuration Application and the Camera’s User Guide.
Symptoms:
•Image has speckling or small spots
•Sharp edges in the image have rings
21