Matrox Electronic Systems 10760-101-0200 Same type and length, Medium Configuration Pin Signal

Page 47

 

Connector pinouts for Matrox Meteor-II /Camera Link for PCI

47

 

 

 

 

Medium Configuration

 

 

 

 

 

 

 

 

Pin

Signal

Pin

Signal

 

 

 

 

 

 

8

DATA, INPUT, Y3+

21

DATA, INPUT, Y3-

 

 

 

 

 

 

9

CLOCK, INPUT , Y+

22

CLOCK, INPUT , Y-

 

 

 

 

 

 

10

DATA, INPUT, Y2+

23

DATA, INPUT, Y2-

 

 

 

 

 

 

11

DATA, INPUT, Y1+

24

DATA, INPUT, Y1-

 

 

 

 

 

 

12

DATA, INPUT, Y0+

25

DATA, INPUT, Y0-

 

 

 

 

 

 

13

INNER SHIELD

26

INNER SHIELD

 

 

 

 

 

 

Use the Camera Link cable from your camera manufacturer or from 3M Interconnect Solutions for Factory Automation, to interface with the above connectors. Note that this cable is not available from Matrox.

 

Manufacturer:

3M Interconnect Solutions for Factory Automation

 

Camera Link cable part number:

14X26-SZLB-XXX-0LC

Caution

If using the two Camera Link connectors, the cables you choose should be of the

 

same type and length.

 

Auxiliary sync and control connector

The expanded auxiliary sync and control connector is a high density DB-44 female connector, located on a separate bracket. It interfaces with the 50-pin auxiliary I/O connector on the board. Note that some signals are duplicated on two pins, and are therefore labeled as A and B. The pinout for this connector is as follows:

pin 15

pin 1

pin 44

pin 31

pin 30

pin 16

Image 47
Contents Matrox Meteor-II /Camera Link Page Contents Hardware reference Appendix B Technical information Page Introduction TTL Matrox Meteor-II /Camera LinkOr Matrox Genesis processor board1 Processing, analysis, and archiving Matrix/bar code reading, and calibrationAcquisition, transfer, display control, and archiving MIL-LiteInspecting the Matrox Meteor-II /Camera Link package What you need to get startedTo your computer and all peripherals Installation overview Introduction Hardware Installation Installing Matrox Meteor-II /Camera Link Screw Metal Plate BIT PCI Board Slot Hardware installation VMChannel. Used to send data to another Matrox board Connecting external devicesMatrox Meteor-II /Camera Link for PC/104-Plus Reference manual for pinout information Connectors pinoutHardware installation Installing software Installing the software Using multiple Matrox Meteor-II Boards Grabbing simultaneously from different boards Multiple board installationGrabbing from two Matrox Meteor-II boards Using multiple Matrox Meteor-II boards Hardware reference Matrox Meteor-II /Camera Link grab section Matrox Meteor-II /Camera Link hardware referenceLUT Max Board are as followsThree ways Each of the video input Camera Link connectorsSection earlier in this chapter Is specified by the DCFVideo Interface Asic Data interfacesPCI interface Hardware reference Appendix a Troubleshooting Common problems and solutions TroubleshootingNot enough memory to allocate buffer under Windows NT IRQ conflicts Contacting Matrox Appendix a Troubleshooting Appendix B Technical Information Technical information Connector pinouts for Matrox Meteor-II /Camera Link for PCI PIN Signal Pinout for the two Camera Link connectors is as followsSame type and length Medium Configuration Pin SignalHDT44P Pin Signal Description Pinout of the 9-pin DB9 female connector is as followsTop view of board Dgnd DATA4 DATA5 DATA6 DATA7 DATA8 DATA9 Extender board Specifications Min. of 6.3 mA recommended Max. of 10 mA recommended Environmental Appendix B Technical information Appendix C Glossary Asic DCF See also progressive scanning Also known as non-interlaced. See also interlaced scanning See also horizontal sync Index Uart EU Notice European Union Regulatory ComplianceFCC Compliance Statement Industry Canada Compliance StatementPage Dorval, Quebec H9P 2T4 Product supportPage Product Assistance Request Form Describe the problem