•Overall Adjustment Mode (Title Display)
This set LCD display
000Assy
: (Disc mark) At end power supply adjustment:Outside lit At end of electrical offset adj.:inside lit
Note:On the set having microcomputer version 1.000,the disc mark is displayed on the set LCD only.
:Left side = MO overall adjustment information F : MO overall adjustment completed
1 : Manual adjustment exists(overall adj.not completed)
0 : Not adjusted
Right side = CD overall adjustment information
F : CD overall adjustment completed
1: Manual adjustment exists(overall adj.not completed)
0: Not adjusted
•Electrical Offset Adjusting Method
Caution: The electrical offset adjustment must be made with no disc loaded.
1.Make sure that the power supply voltage is 3V.
2.Set the test mode (see page 11).
3.Press the . or
This set LCD display
000Assy11
4.Press the [ENTER] key.
This set LCD display
MZ-R501/R501PC
• Adjustment Method of Overall CD and MO Adjustment Mode
1.Setting the test mode (see page 11).
2.Press the . or [VOL
ment mode.
This set LCD display
000Assy
3.Insert CD disc in the set, and press the . key to set the Overall CD Adjustment mode. Automatic adjustments are made.
This set LCD display
X XXCD RUN
XXX: Item number for which on adjustment is being executed.
4.In case of CD overall adjustment NG, reset the NV (see page 17), then readjust from the temperature correction (see page 19).
This set LCD display
0 00 | NG |
: NG item number
5.If OK through the overall CD adjustments, then perform over- all MO adjustments.
This set LCD display
035Ofst
: Adjusted value
5.Electrical offset adjustment is over, if the following display appears.
This set LCD display
0 00CD OK
6.Insert MO disc in the set, and press the > key to set the Overall MO Adjustment mode. Automatic adjustments are made.
This set LCD display
0 00OfstOK | X XXMO RUN |
XXX: Item number for which on | |
| adjustment is being executed. |
7.In case of MO overall adjustment NG, reset the NV (see page 17), then readjust from the temperature correction (see page 19).
This set LCD display
0 00 | NG |
: NG item number
8.If OK through the overall MO adjustments, press the x key to return to the test mode and terminate the Overall Adjustment mode.
This set LCD display
0 00MO OK
21