3M 8422, 8420 Specifications, Dimensions, Electrical requirements, Environmental requirements

Page 16

Specifications

Dimensions

See the 3M™ SelfCheck™ System R-Series Model 8420 and 8422 Site Planning Guide for physical dimensions.

Electrical requirements

The SelfCheckSystem requires compliance with the following electrical specifications:

An outlet within 9.8 feet (3 m) of the system. This is the length of the power cable, which means this is a cable-run specification.

Electrical service of 100 to 120 VAC, 3.0 A, 50/60 Hz, single phase or 200 to 240 VAC, 1.5 A, 50/60 Hz, single phase.

Environmental requirements

Place the SelfCheckSystem in a location that meets the following environmental requirements:

Humidity

0% to 85% RH, non-condensing

 

 

Operating Temperature

50° F to 93° F

 

(10° C to 34° C)

 

 

Storage Temperature

–22° F to 131° F

 

(–30° C to 55° C)

 

 

12

© 3M 2011. All rights reserved.

Image 16
Contents 3M SelfCheck System R-Series Models 8420 Page Contents Contents 3M 2011. All rights reserved Safety information Explanation of signal word consequencesExplanation of product safety label symbols Intended usePage Label locations 3M SelfCheck System R-Series Model 8422 tabletop Regulatory compliance Introduction Key attributesSelfCheck system controls and connections System software Introducing the system to library staff and patronsTurn the system on and off OperationsLoad printer paper Adjust the touch screen monitor Clean system componentsAdjust audio volume Rfid tag reading problems TroubleshootingBarcode scanner problems Specifications DimensionsElectrical requirements Environmental requirementsNetwork requirements SecurityOrdering supplies Warranty Effective3M Service 3M Service phone numbersInformation to gather 3M Library Systems Web Site3M Library Systems