Altinex MT113-101, MT113-100 manual Sta, …S Save, …F Feedback

Page 12

MULTITASKER™

690-0122-015 = Version 015 or later.

690-0123-004 = Version 004 or later.

690-0124-018 = Version 018 or later.

NOTE: In MTSetup™, send the command [VER] from the Terminal Window. The system will respond with feedback similar to the following:

[690-0122-015 690-0123-004 690-0124-018]

Check the last three digits against the numbers above to determine if the option is available.

Command Format: [?CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = from 0 to 9)

The MT113-100/101is in slot #4. Send the command [?C4] to receive the feedback status.

All status feedback is enclosed in brackets, “[ ]“. Each data field within the status is enclosed in parentheses. The first two characters identify the status type. The last three characters are the card’s ID.

[(MT113-100C04)(VR690-0133-009C04) (VO16C04)(VI161616C04)(VB08C04) (VT08C04)(VL01C04)(VM0C04)]

MT113-100

= Card Type

VR690-0133-009

= Firmware version

VO16

= Output Volume Level=16

VI161616

= Input volume levels

VB08

= Bass level = 08 out of 16

VT08

= Treble level = 08 out of 16

VL01

= Loudness (00=ON, 01=OFF)

VM0

= Mute (0=OFF, 1=ON)

The Input Volume status line is read from left to right as outputs one through three. Each volume level is 2 digits, in this case, each is set to 16.

6.[STA]

This command enables/disables automatic feedback from the front panel. The command affects any card with auto-feedback capability, not just the MT113-100/101.The default at power on or reset is STA0, OFF.

Command Format [STA1] = ON

Command Format [STA0] = OFF

Feedback Prefix Definitions:

VR

=

Firmware Version

VO

=

Output Volume

VI

=

Input Volume

VB

=

Bass Volume

VT

=

Treble Control

VL

=

Loudness Control

VM

=

Mute Control

Example:

Command = [VLOA12C04]

Feedback = (VO12C04)

VO = Output Volume

12= Output volume level12

C04 = Card slot number

7.[…S] – SAVE

This command will save the configuration

command being sent in memory. When sending the command [VLBA12C4S], after reset or power up, the bass level on C4 will be 12 out of 16.

8.[…F] – FEEDBACK

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of some command strings.

9.[ + ] and [ - ]

These commands allow a selected property to be adjusted from keyboard commands or programmed front panel buttons.

Command Format: [ + ], [ - ]

[+] = Increment level by one step

[-] = Decrement level by one step

400-0209-002

11

Image 12
Contents MT113-100/101 Table of Contents Precautions / Safety Warnings CleaningGeneral FCC / CE NoticeTechnical Specifications MT113-100/101Description of MT113-100/101 MT113-101 Description Application Diagrams Diagram 3 MT113-100 Internal View Control SupplyDiagram 4 MT113-101 Internal View ControlInstalling Your MT113-100/101 Description of CommandsOperation CnS SavedSTA …S Save…F Feedback Seli SeloSelb SeltVLI VlbaVlta LOD0Volume Ramping Feature MUT1CLR RUPRDN RDN=RST RampCard ID Commands Ramptime = 16 SecondsTest Memory is GoodRSI SIDnSIDnCi SID+Help 38. WRRMC RMGSTA SeliSelo SelbMenu Mode Menu Command DefinitionsCLR RUPUsing Menu Mode Menu Mode ExamplesMenu Types Select this Card for controlTroubleshooting Guide FAN does not SpinNo Sound Limited WARRANTY/RETURN Policy Altinex PolicySound Distortion Sound Level is LOW

MT113-100, MT113-101 specifications

The Altinex MT113-101 and MT113-100 are innovative devices designed to enhance presentation applications in educational and corporate environments. These units are part of Altinex’s commitment to providing high-quality AV solutions, focusing on usability, versatility, and advanced technology.

One of the standout features of the MT113 series is its flexible connectivity options. The MT113-101 and MT113-100 are equipped with a variety of input ports, accommodating different devices and enhancing user experience. The units include HDMI, VGA, and audio inputs, making it easy to connect laptops, desktops, projectors, and other presentation equipment. The ease of connectivity allows users to switch between multiple sources effortlessly, promoting a seamless presentation experience.

Another notable characteristic is the built-in scaling technology. This feature allows the MT113 devices to adjust the resolution of the incoming signal to match the output requirements of the display. This ensures that presentations are delivered with optimal clarity, regardless of the device being used. Consequently, users enjoy crisp visuals and accurate color reproduction, which is vital for effective communication.

The MT113 units also prioritize user-friendliness. Their intuitive design includes straightforward controls, allowing even those with limited technical know-how to operate the system efficiently. This focus on ease of use is essential in environments such as classrooms and conference rooms, where time is often of the essence.

Additionally, the MT113 series is designed with robust build quality in mind. The devices are constructed to withstand the rigors of daily use, making them ideal for high-traffic environments. Their reliability is paramount, especially in corporate settings where presentations can significantly impact outcomes.

Moreover, both models are compact and can be easily integrated into various setups, whether wall-mounted or placed on a tabletop. This flexibility allows organizations to adapt the equipment to their specific spatial and functional needs.

In conclusion, the Altinex MT113-101 and MT113-100 are sophisticated yet user-friendly solutions designed to elevate the presentation experience. With their versatile connectivity options, advanced scaling capabilities, and durable design, these devices are well-suited for a range of applications in educational and professional settings. Their combination of functionality and ease of use makes them a valuable addition to any AV setup.