Specify pinout, distinction between make/break (m1 or b1) and the time (millisecond) when alarm output is specified. Segments are indicated by /. The time is 0 or from 100 to 5000. When the time is 0, alarm output does not come back to previous state.
Setting Example /api/param?application.event(1).action=pinout/m1/1500
Specify preset position number when preset position is specified.
Setting Example
/api/param?application.event(1).action=camera.position(2).status/goto
Specify true_daynight/bw, true_daynight/color, true_daynight/autoH, true_daynight/autoM or true_daynight/autoL when B&W mode is specified.
Setting Example
/api/param?application.event(1).action=camera.image.true_daynight/bw
Alarm action of event number 6 is periodic FTP. Event 1 to 5 can not be set to periodic FTP. Parameters of FTP can be set by another API, application.ftp.
Allowed users admin, operator
Getting Alarm Filter Setting from VN-V686
Format /api/param?application.event(Number).filter(WeekOfDay).status
Example When Getting Setting of Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status
Example of Response application.event(1).filter(sunday).status=off&200 OK
Interpretation Acquire filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. When the filter is enabled, on will be returned. When the filter is disabled, off will be returned.
Allowed users admin, operator
Setting Alarm Filter for VN-V686
Format /api/param?application.event(Number).filter(WeekOfDay).status=data
Example When setting Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status=on
40