Example When Getting Type of Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).type
Example of Response application.event(1).filter(sunday).type=mask&200 OK
Interpretation Acquire filter type of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. "mask" or "unmask" is returned. When the setting is mask, alarm action is disabled during the filter time. When the setting is unmask, alarm action is enabled during the filter time.
Allowed users admin, operator
Setting Alarm Filter Type for VN-V686
Format /api/param?application.event(Number).filter(WeekOfDay).type=data
Example When setting Sunday filter type of Alarm No. 1 to be unmask
/api/param?application.event(1).filter(sunday).type=unmask
Example of Response
application.event(1).filter(sunday).type&202
Accepted(application.event(1).status=restart)
Interpretation Set filter type of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.
Specify mask or unmask. When the setting is mask, alarm action is disabled during the filter time. When the setting is unmask, alarm action is enabled during the filter time.
The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart. Allowed users admin, operator
Getting Alarm Trigger from VN-V686
Format /api/param?application.event(Number).trigger
Example When Getting Trigger of Alarm No. 1
/api/param?application.event(1).trigger
Example of Response application.event(1).trigger=m1&200 OK
Interpretation Acquire Trigger of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
41