Interpretation Change user define name for file naming of periodic FTP. The maximum size is 16 bytes. When /api/param?application.ftp.naming_option is set to "type1", the file name is as ***YYYMMDDHHMMSSNNN.jpg,
and "***" can be set by this API.
File Name Example Camera_20060207201315001.jpg
When /api/param?application.ftp.naming_option is set to "type2", the file name is as ***.jpg and "***" can be set by this API.
File Name Example Camera.jpg
Allowed users admin, operator
Getting Parameters of Pre/Post Recording from VN-V686
Format
To get Frame Rate /api/param?application.object.framerate
To get Pre Duration /api/param?application.object.prerec
To get Post Duration /api/param?application.object.postrec
Example of Response
For Frame Rate application.object.framerate=10&200 OK
For Pre Duration /api/param?application.object.prerec=2&200 OK For Post Duration /api/param?application.object.postrec=2&200 OK
Interpretation Acquire parameters for PrePost + ftp. These parameters are used when recftp is set as an alarm action.
Allowed users admin, operator, user
Setting Parameters of Pre/Post Recording for VN-V686
Format
To set Frame Rate /api/param?application.object.framerate=5
To set Pre Duration /api/param?application.object.prerec=3
To set Post Duration /api/param?application.object.postrec=3
Example of Response
For Frame Rate
For Pre Duration
For Post Duration
Interpretation Change parameters for PrePost + ftp. These parameters are used when recftp is set as an alarm action. Specify 30, 15, 10, 7.5, 6, 5, 3, 2, or 1 for frame rate. Maximum Pre/Post duration is 60 seconds. Setting zero to Pre and Post duration is invalid.
Allowed users admin, operator