Bosch Appliances instruction manual LTC 9384/50 Housings, LTC 9384/20 Housings

Page 11

LTC 9384 Series Instruction Manual Installation

For 24 Volt Cameras:

1.Installing a 24 volt camera into the LTC 9384/60 Housing uses the internal transformer for camera power (see FIGURE 7).

2.Connect the supply (115VAC) to the primary flying leads of the transformer (white wire/pin 1, black wire/pin 6). Use the wire nuts provided for this connection.

3.Connect the secondary flying leads (white/black striped wires/pins 7 and 12) to the camera's

24 volt input. See wiring diagram FIGURE 8 for clarification and FIGURE 5 for power connection drawings.

To Heater/Defogger

EN 11

 

 

To Heater/Defogger

 

 

 

 

Red

Black

6

12

White/

 

 

 

 

Black

 

 

 

 

Striped

 

24 VAC

 

24 VAC

To Camera

Input

 

 

 

 

 

 

 

 

White/

 

 

1

7

Black

 

White

Striped

 

 

 

 

 

Red

To Heater/Defogger

FIGURE 9 LTC 9384/20 Transformer Wired for 24 Volt Camera

5.6.6 LTC 9384/50 Housings

These housings require connection to 230VAC, and are designed for use where the site power is 230 volts.

 

 

 

 

Red

Black

6

12

White/

 

 

 

 

Black

 

 

 

 

Striped

 

115 VAC

5

11

 

 

 

 

24 VAC

To Camera

Input

 

 

2

8

 

 

 

 

 

 

 

 

White/

 

White

1

7

Black

 

Striped

 

Red

The LTC 9384/50 Housings can easily be used with either 230 volt or 24 volt cameras.

The internal transformer provides 24VAC for both the heater and 24 volt camera power.

Do not remove the transformer insulator. No user serviceable parts are present.

FIGURE 8 LTC 9384/60 Transformer Wired for 24 Volt Camera

5.6.5 LTC 9384/20 Housings

These housings are to be connected to 24VAC only, and are designed for use where the site power is 24 volts.

The LTC 9384/20 housings are designed to be used with 24 volt cameras only.

1. Connect the supply (24VAC) to the primary flying

leads of the transformer. Use the wire nuts

provided for this connection (see FIGURE 9).

For 230 Volt Cameras:

1.Installing a 230 volt camera into the LTC 9384/50 housing requires the camera's line cord to be cut and connected with the transformer's primary wiring and the power supply line (see FIGURE 10).

2.The secondary flying leads (white/black striped) will not be used in this application, and should be taped to prevent shorting. See wiring diagram FIGURE 10 for clarification and FIGURE 5 for power connection drawings.

To Camera

To Heater/Defogger

Brown

2. Connect the secondary flying leads to the camera's

24 volt input. See wiring diagram FIGURE 9 for

clarification and FIGURE 5 for power connection

drawings.

Connector Black 6

5

230 VAC Input

2

Connector Blue 1

Blue

To Camera

12White/ Black

 

Striped

11

 

 

24 VAC No Connection

8

 

 

White/

7

Black

Striped

To Heater/Defogger

FIGURE 10 LTC 9384/50 Transformer Wired for 230 Volt Camera

Bosch Security Systems September 1, 2004

Image 11
Contents LTC 9384 Series Bosch Security Systems September 1 Important SafeguardsFor Rack-mount Product For Indoor ProductFor Outdoor Product SicherheitshinweiseSécurité Medidas de Segurança Sicurezza Table of Contents Model Designation Service CentersEnclosure Rating Cradle Removal Tools Required Cable Requirements Plug Insertion Camera/Lens InstallationCamera/Lens Wiring GeneralLTC 9384/60 Housings Power ConnectionsLTC 9384/20 Housings LTC 9384/50 HousingsVideo Coax Connection Lens WiringFinal Assembly Pull Seal InstallationBreather Hole Cradle AssemblyExploded View Parts List Bosch Security Systems September 1 Bosch Security Systems GmbH