LTC 9384 Series Instruction Manual Installation
For 24 Volt Cameras:
1.Installing a 24 volt camera into the LTC 9384/60 Housing uses the internal transformer for camera power (see FIGURE 7).
2.Connect the supply (115VAC) to the primary flying leads of the transformer (white wire/pin 1, black wire/pin 6). Use the wire nuts provided for this connection.
3.Connect the secondary flying leads (white/black striped wires/pins 7 and 12) to the camera's
24 volt input. See wiring diagram FIGURE 8 for clarification and FIGURE 5 for power connection drawings.
To Heater/Defogger
EN 11
|
| To Heater/Defogger | ||
|
|
|
| Red |
Black | 6 | 12 | White/ |
|
|
|
| Black |
|
|
|
| Striped |
|
24 VAC |
| 24 VAC | To Camera | |
Input |
| |||
|
|
|
| |
|
|
| White/ |
|
| 1 | 7 | Black |
|
White | Striped |
| ||
|
|
|
| Red |
To Heater/Defogger
FIGURE 9 LTC 9384/20 Transformer Wired for 24 Volt Camera
5.6.6 LTC 9384/50 Housings
These housings require connection to 230VAC, and are designed for use where the site power is 230 volts.
|
|
|
| Red |
Black | 6 | 12 | White/ |
|
|
|
| Black |
|
|
|
| Striped |
|
115 VAC | 5 | 11 |
|
|
|
| 24 VAC | To Camera | |
Input |
|
| ||
2 | 8 |
|
| |
|
|
| ||
|
|
| White/ |
|
White | 1 | 7 | Black |
|
Striped |
|
Red
The LTC 9384/50 Housings can easily be used with either 230 volt or 24 volt cameras.
The internal transformer provides 24VAC for both the heater and 24 volt camera power.
Do not remove the transformer insulator. No user serviceable parts are present.
FIGURE 8 LTC 9384/60 Transformer Wired for 24 Volt Camera
5.6.5 LTC 9384/20 Housings
These housings are to be connected to 24VAC only, and are designed for use where the site power is 24 volts.
The LTC 9384/20 housings are designed to be used with 24 volt cameras only.
1. Connect the supply (24VAC) to the primary flying |
leads of the transformer. Use the wire nuts |
provided for this connection (see FIGURE 9). |
For 230 Volt Cameras:
1.Installing a 230 volt camera into the LTC 9384/50 housing requires the camera's line cord to be cut and connected with the transformer's primary wiring and the power supply line (see FIGURE 10).
2.The secondary flying leads (white/black striped) will not be used in this application, and should be taped to prevent shorting. See wiring diagram FIGURE 10 for clarification and FIGURE 5 for power connection drawings.
To Camera | To Heater/Defogger |
Brown
2. Connect the secondary flying leads to the camera's |
24 volt input. See wiring diagram FIGURE 9 for |
clarification and FIGURE 5 for power connection |
drawings. |
Connector Black 6
5
230 VAC Input
2
Connector Blue 1
Blue
To Camera
12White/ Black
| Striped |
11 |
|
| 24 VAC No Connection |
8 |
|
| White/ |
7 | Black |
Striped |
To Heater/Defogger