LTC 9384 Series Instruction Manual Installation
For 24 Volt Cameras:
1.Installing a 24 volt camera into the LTC 9384/50 housing uses the internal transformer for camera power (see FIGURE 11).
2.Connect the supply (230VAC) to the terminal block. Use only the terminal block provided for this connection.
3.Connect the secondary flying leads to the camera's 24 volt input. Refer to the wiring diagram for clarification.
|
|
| To Heater/Defogger | |
|
|
|
| Red |
Brown | 6 | 12 | White/ |
|
|
|
| Black |
|
|
|
| Striped |
|
230 VAC | 5 | 11 |
|
|
|
| 24 VAC | To Camera | |
Input |
|
| ||
| 8 |
|
| |
| 2 |
|
| |
|
|
| White/ |
|
Blue | 1 | 7 | Black |
|
Striped |
|
Red
To Heater/Defogger
FIGURE 11 LTC 9384/50 Transformer Wired for 24 Volt Camera
5.7Video Coax Connection
WARNING: Use only the cables specified under INSTALLATION, Cable Requirements for video coax wiring connection.
If no lens control or
1.Install the seal cap portion of the large liquid- tight fitting on the video coax cable, and pull the cable through the
2.Attach the BNC connector to the coax and connect it to the camera. Pull any excess wire out of the cradle assembly and tighten approximately 1 to 11⁄2 turns past the point where the fitting starts to grip the wire. Failure to do so will result in water damage to all electronic parts. Use a tie wrap (included) to provide strain relief on the video cable at the exit point (inside the unit).
EN 12
3.Install the 3⁄8in. NPT plug provided in the unused, small top center NPT hole.
Securely tighten all fittings to ensure a liquid- tight seal. Failure to do so could allow water to enter the housing and damage the camera and lens.
5.8Lens Wiring
WARNING: Use only the cables specified under INSTALLATION, Cable Requirements for video coax wiring connection.
1.If installing a zoom lens, insert the lens control cable with the installed seal cap in through the right fitting at the rear of the cradle. Attach the lens wiring to the lens mating connector and connect it to the lens. If the mating connector is not available, connect directly to the lens cable.
NOTE: See the specification on lens cord for the correct plug connection.
Securely tighten all fittings to ensure a liquid- tight seal. Failure to do so could allow water to enter the housing and damage the camera and lens.
2.If using a pan/tilt with a
Use of drip loops is not recommended on the wiring outside of the rear endcap.
5.9Final Assembly
5.9.1Pull Seal Installation
If the breather hole is open, do NOT mount the housing in a position where the front endcap is pointed upward.
To maintain enclosure protection ratings of