Axis Communications M3014 Problems with streaming H.264, Key frames, Video Camera Settings

Page 48

AXIS M3014 Network Camera

Troubleshooting

Problems with streaming H.264

Problems with AXIS Media Control (Internet Explorer only)

To enable the updating of video images in Internet Explorer, set the browser to allow ActiveX controls. Also, make sure that AXIS Media Control is installed on your computer.

No H.264 displayed in the

Check that the relevant H.264 connection methods and correct interface are enabled in the AMC

client

Control Panel (streaming tab). See AXIS Media Control (AMC) on page 11 .

 

In the AMC Control Panel, select the H.264 tab and click Set to default H.264 decoder.

 

Check that RTSP is enabled under System Options > Network > TCP/IP > Advanced.

Multicast H.264 only

Check if your router supports multicasting, or if the router settings between the client and the

accessible by local clients

product need to be configured. The TTL (Time To Live) value may need to be increased.

No multicast H.264

Check with your network administrator that the multicast addresses used by the Axis product

displayed in the client

are valid for your network.

 

Check with your network administrator to see if there is a firewall preventing viewing.

Installation of additional

Configure the Axis product to use a Java applet for updating video images in your browser. Go to

ActiveX component

Setup > Live View Config and select Java applet under Default viewer.

restricted or prohibited

 

Poor rendering of H.264

Ensure that your graphics card is using the latest driver. The latest drivers can usually be

images

downloaded from the manufacturer’s website.

Color saturation is different

Modify the settings for your graphics adapter. Refer to the adapter’s documentation for more

in H.264 and Motion JPEG

information.

Lower frame rate than

See Performance Considerations on page 51.

expected

Reduce the number of applications running on the client computer.

 

 

Limit the number of simultaneous viewers.

 

Check with the network administrator that there is enough bandwidth available.

 

Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only

 

key frames.

 

Lower the image resolution.

 

The maximum frames per second is dependent on the utility frequency (60/50 Hz) of the Axis

 

product. See Technical Specifications on page 49.

Status and Network indicator LEDs are flashing red rapidly

 

 

Hardware failure

Contact your Axis reseller.

Video and image problems, general

 

 

Image unsatisfactory

Check the video stream and camera settings under Setup > Video > Video Stream and Setup >

 

Video > Camera Settings.

Motion Detection triggers unexpectedly

 

 

Changes in luminance

Motion detection is based on changes in luminance in the image. This means that if there are

 

sudden changes in the lighting, motion detection may trigger mistakenly. Lower the sensitivity

 

setting to avoid problems with luminance.

48

Image 48
Contents Axis M3014 Network Camera About this document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis M3014 Network CameraHardware Overview Connectors and Buttons LED IndicatorsNetwork Connector Control ButtonAccess the Product Access from a BrowserAccess from the Internet Set the Root PasswordSet Power Line Frequency Live ViewClick Create self-signed certificate Go to Setup Events Controls on the Live ViewAxis Media Control viewer toolbar Manual TriggerPTZ Controls How to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream Axis M3014 Network Camera Set Up the Product Basic SetupVideo Video StreamPixel Counter ImageStream Profiles 264Camera Settings Exposure SettingsView Area Image AppearanceOverlay Overlay ImageGo to Video Video Stream and select the Image tab Go to Video Overlay ImagePrivacy Mask Configure the Live View Default Viewer for BrowsersViewer Settings Browser Viewer DescriptionUser Defined Links Preset Positions PTZ Pan Tilt ZoomGuard Tour Advanced ControlsDetectors Camera TamperingMotion Detection Go to Detectors Camera TamperingSet Up Motion Detection Windows Motion Detection ParametersAxis M3014 Network Camera Install Application Go to Setup ApplicationsApplications Application LicensesAxis M3014 Network Camera Set Up Action Rules EventsConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers ActionsRecipients Create SchedulesRecipient Use with action Go to Events Recipients and click AddSet Up Recurrences Go to Events Recurrences and click AddRecordings Recording ListContinuous Recording Go to Recordings ListLanguages System Options SecurityUsers IP Address FilterIeee CertificatesCertificates Basic TCP/IP Settings Go to Setup System Options Security CertificatesDate & Time NetworkIPv4 Address Configuration IPv6 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAdvanced TCP/IP Settings Axis Internet Dynamic DNS ServiceDNS Configuration Axis Video Hosting System AvhsNTP Configuration Host Name ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailUPnPTM can be disabled under System Options Network UPnPTM UPnPTMRTP/H.264 BonjourMaintenance StorageNetwork Share Go to System Options Storage Click Network ShareSupport Support OverviewSystem Overview Logs & Reports Reset to Factory Default Settings Plain Config File Upload Troubleshooting Upgrade the FirmwareEmergency Recovery Procedure Check the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyProblems with streaming H.264 Status and Network indicator LEDs are flashing red rapidlyVideo and image problems, general Video Camera SettingsTechnical Specifications Function/group Specifications System Application Maintenance Installation aidsPower ConnectorsFunction/group Specifications Video Performance ConsiderationsM2.6
Related manuals
Manual 49 pages 56.04 Kb