Power connection

1.Use a class 2 power supply 24 VAC or +12 VDC.

2.Connect the power wires (red+ , brown-) to the power supply.

3.Connect the earth wire (yellow/green) from the camera to the system earth of the installation to ensure correct EMC/ RFI and safety protection.

Network (and PoE) connection

1.Use a shielded twisted pair (STP) Category 5e cable, maximum length 100 meters.

2.Use the RJ45 female-to-female network cable connector to connect the network cable of the system to the RJ45

connector of the camera (Auto MDIX compliant - automatically detects the cable connection type).

Power is supplied to the camera via the Ethernet cable, compliant with the Power-over-Ethernet standard.

Note:

The RJ45 female-to-female network cable connector supplied is unshielded.

To comply with the EMC Alarm immunity standard (EN50130-4) or the EMC Railway immunity standard (EN50121-4), a shielded twisted pair (STP) connection cable and a shielded RJ45 female-to-female network cable connector (not supplied) should be used.

Alarm Input

Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make or break contact can be used as the actuator (use a bounce-free contact system).

Refer to the cable tree table to identify the wire colors for connecting the alarm input.

Configurable as active low or active high.

Bosch Security Systems

Installation Manual

AM18-Q0615 v1.0 2012.10

Image 25
Contents Flexidome HD 1080p HDR RD Page Table of Contents Camera configuration InstallationTroubleshooting MaintenanceTechnical Data Safety precautions SafetyImportant safety instructions Type label Connection in applicationsGrounding FCC & Ices Information FCC & Ices complianceUL certification MicroSD cardsDisclaimer Bosch notices Copyrights Introduction FeaturesOverview of functions System InformationPower-over-Ethernet Alarm I/OAudio Tamper detection and motion detectionRecording ConfigurationBosch Video Management System Operation with external systemsBosch Video Client Bosch Recording StationUnpacking PlanningSystem requirements Parts InstallationSurface mounting Mounting the unitFlexidome HD Figure?5.2?Flush mounting Flush mountFlexidome HD Signal Wire colorConnections Make the connectionsAlarm Input Power connectionNetwork and PoE connection Audio in / Audio out Alarm outputMount the camera module Opening the camera module Controls Camera set-up 1 Pan Camera positioningTilt Twist Adjustment procedure Using the install wizardClosing the unit Day/Night switching Camera configurationUser modes Protected network Browser connectionFunction test TroubleshootingMalfunction Possible causes Solution Resolving problemsLivepage Functions For example 192.168.0.80/version Customer serviceTesting the network connection MaintenanceRepairs Transfer and disposalSpecifications Technical DataIP, IBP, Ibbp 10.1.1 Dimensions Flexidome HD Page Bosch Security Systems