FLEXIDOME HD | Installation en 25 |
|
|
Power connection
1.Use a class 2 power supply 24 VAC or +12 VDC.
2.Connect the power wires (red+ ,
3.Connect the earth wire (yellow/green) from the camera to the system earth of the installation to ensure correct EMC/ RFI and safety protection.
Network (and PoE) connection
1.Use a shielded twisted pair (STP) Category 5e cable, maximum length 100 meters.
2.Use the RJ45
connector of the camera (Auto MDIX compliant - automatically detects the cable connection type).
Power is supplied to the camera via the Ethernet cable, compliant with the
Note:
The RJ45
To comply with the EMC Alarm immunity standard
Alarm Input
Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make or break contact can be used as the actuator (use a
–Refer to the cable tree table to identify the wire colors for connecting the alarm input.
–Configurable as active low or active high.
Bosch Security Systems | Installation Manual |