Panasonic Features, Connections, WV-CP460 120 V AC 60 Hz, WV-CP464 12 V DC/24 V AC

Page 2

FEATURES

1.The following functions are built in.

(1)Auto Light Control (ALC)/Electronic Light Control (ELC)

(2)The SUPER-D2function eliminates interference by strong background lighting which makes the camera picture dark, such as a spotlight.

Dynamic range of 46 dB.

(3)Various External Sync Functions, including Gen-Lock

(4)Auto/Manual White Balance Function

(5)Electronic Shutter Function

2.Signal-to-noise ratio of 50 dB

3.Minimum illumination of 0.8 lx (0.08 footcandle) with F 1.4 lenses.

4.Minimum illumination of 0.4 lx (0.04 footcandle) with Panasonic aspherical high speed (F0.75) lenses.

5.480 lines of horizontal resolution

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

 

q w e r

<WV-CP460>

 

 

 

 

 

 

 

!4

 

 

 

120V

AC 60Hz

VIDEO OUT

 

 

 

 

Super Dynamic

 

 

GEN-LOCK

 

 

 

 

WV-CP460

 

 

 

 

LOCK

 

 

 

 

t

 

 

 

!1

i

<WV-CP464>

 

 

 

 

 

 

DC 12V

AC 24V

 

Hi-Z G/L 75

 

IN

INVIDEO OUT

 

 

 

 

 

 

!5

1

 

 

o

2

 

 

 

GEN-LOCK

 

y

 

 

 

 

GND

 

u!0

!3

!2

!3

!2

Slide the panel to the left until it locks.

qAuto Iris Lens Connector

This connector is used to connect the auto iris lens with a 4-pin male connector sup- plied as a standard accessory (Part No. YFE4191J100).

wFocus Fixing Screw

eFlange-back Adjusting Ring

This ring is used to adjust the back focal length or picture focus. Rotate this ring clock- wise for a C-mount lens or counterclockwise for a CS-mount lens.

rLens (Option)

tCamera Mounting Screw Hole

This hole is used to mount the camera onto a mounting bracket.

CONNECTIONS

A. WV-CP460 (120 V AC 60 Hz)

1.Plug the AC power cord (supplied as standard accessory) into the AC Inlet Socket.

2.Connect the AC power cord to a 120V AC 60 Hz outlet.

Notes:

Connect the power cord firmly.

The power cord should be long enough for panning and tilting.

If the cable is too short, the power cord plug may be pulled off the camera when the camera pans or tilts.

B.WV-CP464 (12 V DC/24 V AC)

The WV-CP464 has an AC/DC compatible input terminal. The 12 V DC or 24 V AC power supply cord can be connected to this terminal. The camera detects the power source auto- matically.

1.12 V DC Power Supply

Connect the power cord to the AC/DC compatible input terminal on the rear panel of the camera.

DC 12V

AC 24V

 

 

Resistance of copper wire [at 20°C (68°F)]

 

IN

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Copper wire

#24

#22

#20

#18

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

size (AWG)

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance

0.078

0.050

0.030

0.018

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 V DC

/m

 

 

 

 

 

 

 

 

 

GND

 

(10.8 V - 16 V)

 

 

 

 

 

 

 

 

 

 

 

Resistance

0.026

0.017

0.010

0.006

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Calculation of maximum cable length between camera and power supply

10.8V DC VA - (R x 0.42 x L) 16 V DC

L : Cable length (m)

R : Resistance of copper wire (/m)

VA : DC output voltage of power supply unit

L standard =

VA

12

 

(m)

 

 

 

 

 

 

0.42 x R

L minimum =

VA

16

 

(m)

 

 

 

 

 

 

0.42 x R

L maximum =

VA

10.5

 

(m)

 

 

 

 

 

 

0.42 x R

Image 2
Contents Precautions PrefaceWV-CP460 120 V AC 60 Hz FeaturesConnections WV-CP464 12 V DC/24 V AC3Video Output Connector Video OUT 1Gen-lock Termination Switch Hi-Z, G/L 75 Ω2Gen-lock Input Connector GEN-LOCK AC Power SupplyMounting from the top Focus or FLANGE-BACK AdjustmentInstallation of Camera Editing the CAM SET UP Menu SetupOpening the Setup Menu Light Control Setting ALC/ELC Setting ProceduresCamera Identification Camera ID Setting ALC Mode with SUPER-D2 onSynchronization Setting Sync Shutter Speed Setting ShutterGain Control Setting AGC ON/OFF ALC Mode with SUPER-D2 OFF and ELC ModeVBS Gen-lock Mode EXT VBS VS Gen-lock Mode EXT VSAuto-Tracing White Balance Mode ATW White Balance Setting White BALLine-lock Sync Mode LL Fine Adjustment for AWC ATW ManuallySpecial Menu Motion Detector Setting Motion DETLens Drive Signal Selection Lens Drive Optional Accessories SpecificationsStandard Accessories Panasonic Canada Inc