Panasonic WV-CP460, WV-CP464 White Balance Setting White BAL, Line-lock Sync Mode LL

Page 9

8. Adjust the horizontal phase by pressing or . The adjustable range is 0-2.0 µs.

6-3. Line-lock Sync Mode (LL)

Note: The line-lock (LL) sync mode is not available when the camera operates on DC power.

1.Move the cursor to the SYNC parameter and select LL.

Note: The settings in this menu can be made only when the multiplexed vertical drive signal (VD2) is not supplied to the camera.

2.After confirming that the cursor is on

LL, press

. The vertical phase

 

 

 

adjustment menu appears on the moni-

 

** SYNC **

tor.

 

V PHASE

 

3. Supply the

video output signal of the

COARSE

 

1(1--16)

camera to be adjusted and the refer-

FINE

I

ence camera video output signal to a

 

-

+

dual-trace oscilloscope.

4. Set the oscilloscope to the vertical rate

RET END

 

and expand the vertical sync portion on

 

the oscilloscope.

 

5.Move the cursor to COARSE.

6.Press or to match the vertical phase for both video output signals as closely as

possible. (COARSE adjustment can be incremented in 16 steps by 22.5 degrees by

pressing or .)

Note: After the sixteenth step, the adjustment returns to the first step.

7.

Move the cursor to FINE.

 

 

 

 

 

 

 

1

(1 - - 16): 0 degrees

8.

Press

or

to match the vertical

2

(1 - - 16): 22.5 degrees

 

phase for both video output signals as

 

 

 

 

 

closely as possible.

 

 

 

 

 

 

(FINE adjustment can be made up to

16 (1 - - 16): 337.5 degrees

 

22.5 degrees by pressing

or

.)

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the “I” cursor reaches the “+” end, it jumps back to “–”. At the same time, COARSE is incremented by one step to enable a continuous adjustment. The reverse takes place when the “I” cursor reaches the “–” end.

When or is kept pressed for a second or more, the “I” cursor moves faster.

To reset COARSE and FINE to the values preset at the factory, press or simultaneously. COARSE and FINE adjustments are preset at the factory to zero- crossing of the AC line phase.

If the AC line contains noise (spike noise, etc.), the stability of the vertical phase of the camera video output signal may be disturbed.

7.White Balance Setting (WHITE BAL)

7-1. Auto-Tracing White Balance Mode (ATW)

You can select one of two modes for white balance adjustment as follows:

ATW (Auto Tracing White Balance)

In this mode, the color temperature is monitored continuously and thereby white bal- ance is set automatically. The color temperature range for the proper white balance is approximately 2 600 - 6 000K. Proper white balance may not be obtained under the fol- lowing conditions:

1.The color temperature is out of the 2 600 - 6 000K range.

2.When the scene contains mostly high color temperature objects, such as a blue sky or sunset.

3.When the scene is dim.

In these cases, select the AWC mode.

Move the cursor to the WHITE BAL parameter and select ATW. The white balance of the camera is automatically set.

Automatic White Balance Control Mode (AWC)

 

 

 

 

 

In this mode, accurate white balance is obtained within a color temperature range of

 

approximately 2 300-10 000K.

 

 

 

 

 

1.

Move the cursor to the WHITE BAL

 

 

 

 

 

parameter and select AWC

PUSH

** CAM SET UP **

 

SW.

 

 

CAMERA ID

 

OFF

 

 

 

ALC/ELC

 

ALC ↵↵

 

 

 

 

SHUTTER

 

OFF

2.

Press

to start the white

balance

AGC

 

ON

SENS UP

 

OFF

 

setup. The PUSH SW is highlighted to

SYNC

 

INT

 

WHITE BAL

 

AWCPUSH SW

 

 

indicate that the white balance is being

MOTION DET

OFF

 

 

LENS DRIVE

DC

 

set.

 

 

END

SET UP ENABLE

 

 

 

 

3.When the white balance setting is com- pleted, the PUSH SW returns to normal display.

Note: In case that the white balance is not set, the PUSH SW Is being highlighted.

4.When you want to adjust the white bal-

ance manually, press to select

AWC and press . The AWC menu appears on the monitor. (When ATW is

selected, pressing displays the ATW menu.)

** AWC **

R....I....

- +

B....I....

- +

MASK SET

RET END

Fine Adjustment for AWC (ATW) Manually

You can add the detailed setting for white balance setting manually.

1.To set MASK SET, proceed as described in steps 2 to 4 of “ALC mode with SUPER-D2 OFF and ELC mode”.

2.Move the cursor to R.

3.Press or to obtain the optimum amount of red gain.

4.Move the cursor to B.

5.Press or to obtain the optimum amount of blue gain.

Note: When you need to set MASK SET, re-adjust to obtain the optimum amount of red and blue gain.

Image 9
Contents Preface PrecautionsConnections FeaturesWV-CP460 120 V AC 60 Hz WV-CP464 12 V DC/24 V AC2Gen-lock Input Connector GEN-LOCK 1Gen-lock Termination Switch Hi-Z, G/L 75 Ω3Video Output Connector Video OUT AC Power SupplyFocus or FLANGE-BACK Adjustment Installation of CameraMounting from the top Setup Opening the Setup MenuEditing the CAM SET UP Menu Camera Identification Camera ID Setting Setting ProceduresLight Control Setting ALC/ELC ALC Mode with SUPER-D2 onGain Control Setting AGC ON/OFF Shutter Speed Setting ShutterSynchronization Setting Sync ALC Mode with SUPER-D2 OFF and ELC ModeVS Gen-lock Mode EXT VS VBS Gen-lock Mode EXT VBSLine-lock Sync Mode LL White Balance Setting White BALAuto-Tracing White Balance Mode ATW Fine Adjustment for AWC ATW ManuallyMotion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Standard Accessories SpecificationsOptional Accessories Panasonic Canada Inc