AXIS 213 PTZ 28
6.Adjust the Object size, History and Sensitivity profile sliders (see table below for details). Any detected motion within an active window is then indicated by red peaks in the Activity window (the active window has a red frame).
7.Click Save.
If there are parts of the Include window that you wish to exclude, click the
Configure Excluded Windows radio button and repeat steps
Please see the online help for descriptions of each available option.
Parameter | Size | History | Sensitivity |
|
|
|
|
High | Only very large objects | An object that appears in the region | Ordinary colored objects against ordi- |
| trigger motion detection | will trigger the motion detection for a | nary backgrounds will trigger the |
|
| long period | motion detection |
|
|
|
|
Low | Even very small objects | An object that appears in the region | Only very bright objects against a dark |
| trigger motion detection | will trigger motion detection for only a | background will trigger motion detec- |
|
| very short period | tion |
|
|
|
|
Default val- | Low | Medium to High | Medium to High |
ues |
|
|
|
|
|
|
|
Examples:
•Avoid triggering on small objects in the image by selecting a high size level.
•To trigger motion detection as long as there is activity in the area, select a high history level.
•To only detect flashing light, low sensitivity can be selected. In other cases, a high sensitivity level is recommended.
Port Status
Under Event Configuration > Port Status there is a list that shows the status for the connected inputs and outputs of the AXIS 213 PTZ for the benefit of the Operator who cannot access the System Options section.
Example: If the Normal state for a push button connected to an input is set to Inactive - as long as the button is not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.