Viewing Live Video

 

Table 4-4

Camera Video & Control Window Controls (continued)

 

 

 

 

Control

 

Description

 

 

 

 

Restore button

 

Displays the default video image, which is not rotated and not reversed.

 

 

 

Full Screen button

Displays the video image in full screen mode.

 

 

To return to normal display mode, click the full screen image.

 

 

 

Motion detection

 

 

Up Arrow toggle button

Down Arrow toggle button

Click the Up Arrow to display the motion detection controls. The button changes to the Down Arrow button.

Click the Down Arrow button to hide the motion detection controls. The button changes to the Up Arrow button.

Motion detection controls

Note These controls appear when you click the Up Arrow in the Motion Detection area and are available only viewing the primary (H.264) stream.

Enable Motion Detection check box

Enables the motion detection feature and displays a grid over the video image.

When motion detection is enabled, the IP camera monitors activity in the video field areas that you specify. If activity at a defined level occurs in any of these areas, the IP camera generates an alert and takes the configured actions.

To designate specific areas that the IP camera monitors for activity, select the areas by clicking each grid cell over the area. A red border indicates a selected area. To deselect an area, click it again.

You can configure the following levels for areas that the IP camera monitors for activity:

Sensitivity—Designates the relative amount of activity that the IP camera must detect in the area before it generates an alert. A lower value means that more, or faster, activity is required to trigger an alert. A higher value means that less, or slower, activity is required. The default value is 80.

Threshold—Designates the percentage of pixels that the IP camera must identify as changed in the area before it generates an alert. The camera detects pixel changes at the defined sensitivity level. The default threshold value is 10.

To configure sensitivity or threshold, right-click a grid cell that has a red border and then drag the Sensitivity and Threshold sliders to the desired values. Alternatively, enter a value from 1 through 100 for an option and press the Enter key. To reset the sensitivity and threshold to their default values of 50, click Restore. These configuration settings affect the cell that you select. If the cell is part of a group of horizontally or vertically (but not diagonally) adjacent cells, the settings affect all cells in the group.

Cisco Video Surveillance 7030 IP Camera Installation Guide

 

OL-28692-01

4-7

 

 

 

Image 31
Contents Americas Headquarters Cisco Video Surveillance 7030 IP Camera Installation GuideCisco Video Surveillance 7030 IP Camera Installation Guide N T E N T S OL-28692-01 Organization OverviewOL-28692-01 Introduction OverviewPackage Contents IP Camera Physical Details IP Camera Physical FeaturesVideo output External microphonePin Description General Purpose I/O Terminal BlockOL-28692-01 Installation Guidelines Camera InstallationCamera Installation Camera Installation Procedure Installing the IP Camera with a Vandal Resistant EnclosurePage Place the screw nut E on the power and I/O cable opening 3 4 5 6 7 Cisco Video Surveillance 7030 IP Camera Installation Guide What to do next OL-28692-01 Before you Begin Performing the Initial Setup of the IP CameraProtocol//ipaddress Home Understanding the IP Camera User InterfaceLink Description RefreshField Description IO Port Status Adjusting the IP Camera Focus and ZoomStream 1 and Stream Resetting the IP Camera Powering the IP Camera On or OffReset Type Procedure Remarks Video image controls Viewing Live VideoControl Description Video controlsSave Snapshot button Restore buttonImage tools Hotspot Zoom button Hotspot Pan/TiltFull Screen button Motion detection controls Enable Motion Detection check boxMotion detection Focus/Zoom Save Settings buttonReset button Full Screen checkD E IN-2 IN-3 IN-4