Samsung SCC-C7478 manual Installation Using Mount Bracket, RS-485 Termination Resistor

Page 10

Installation

RS-485 Termination Resistor

ON ON

1 2 3 4 5 6 7 8

Pin 8 is used for ON/OFF of RS-485 Termination. Normally, it must be OFF state. Especially when you have trouble with long Daisy chain style connection, turn ON this termination switch of last camera.

– Pin 8 RS-485 Termination Resistor (On/Off)

INSTALLATION USING MOUNT BRACKET

Using the paper template, mark the holes on the wall.

After locating the wall mount bracket on the anchor bolts properly. Tighten the nuts for anchor bolts



After drilling the holes, fi x the four anchor bolts into the holes.



 

 

Connect cables to terminal blocks and BNC in the inner box of junction box. See the cabling in the next section.

C onnector to the dom e cam era

Protocol,

Address DIP

RS-485

ALAR M

P O W ER

B N C

VIDEO

10 – 36x SMART DOME CAMERA

Image 10
Contents 36x Smart Dome Camera Please register your product atSafety information English Important Safety Instructions Contents Features Introduction Housing Safety Cable Hanger Hole Template User’s Guide Product & Accessories Accessories ProductDome Cover Parts Name & FunctionsInner box Communication Protocol Setup InstallationDIP Switch Setup Camera ID SetupInstallation Using Mount Bracket RS-485 Termination ResistorInstallation 12 36x Smart Dome Camera Cabling Power ConnectionRS-485 Communication Connect with BNC coaxial cable Alarm Input ConnectionVideo Connection Sensor InputOperation Pattern PresetAuto PAN Delete Auto Pan To delete Auto Pan, use OSD menuSchedule ScanOther Functions OSD Display of Main Screen Preset ×××Pattern × AUP×/PRESET ××× Undefined General Rules of KEY Operation for MenuPrivacy Zone Mask Setup How to use OSD MenuDisplay Setup Main MenuPrivacy Zone Area Setup Motion SetupPrivacy Zone Size Adjustment Alarm Input Setup Function SetupParking Action Setup HOME/PRESET/PATTERN/AUTOPAN/SCANEdit Preset Label Preset SetupEdit Preset Scene CANCEL/OKClear Apanauto PAN CANCEL/OK Deletes current Auto Pan data Auto PAN SetupPattern Setup Back Space CharEdit Pattern Scan SetupEdit Scan Action no NONE/PRESET/AUTO PAN/PATTERN④ Set up items such as Action, NO., Dwell and OPT OPTSchedule Setup Edit ScheduleCamera Setup White Balance SetupIris System SetupPASSWORD, Home POSITION, North Position GainSet Home Position? Password SetupSet North Direction You can set up North direction It is noted that Master PsswordSystem Initialize Initial Configuration TableAppearance SpecificationsSpecifi cations Wall Mount Ceiling MountWall Mount Bracket DimensionCeiling Mount Bracket