Grandstream Networks manual HT503 FXO Port Configuration

Page 5

Figure 1-4: HT503 FXO Port Configuration

Below (Figure 1-4) is the FXO Port related configuration. Please configure only the mentioned parameters and do not change and leave all other parameters as default:

Account Active:

Yes

SIP User ID: Use any digits you want. HT503 just need some digits here to send to surveillance box therefore you can put ANY digits here. Here “110” is used as example.

SIP Registration:NO

This is very important as there is NO SIP Server involved and we just manipulate the IP of each other device to make them work with each other.

Outgoing Call w/o Registration: YES

This is important also because NO SIP Server therefore no credentials involved here. The application is assumed in a secure and trusted LAN environment.

Local SIP Port:

5062

This is the port HT503 FXO port will listen to.

5

Image 5
Contents Pre-Request Surveillance Solution How To Do It?Application Network Schema ConfigurationHT503 Status HT-503 ScenarioHT503 IP Configuration HT503 FXO Port Configuration HT503 FXO Port Configuration HT503 FXS Port Configuration Optional Surveillance Device Scenario GXV3XXX IPC or DVS IP Address Setting of Surveillance ProductsSIP Configuration of Surveillance Products Motion Detection Configuration Motion Detection Configuration Smtp Setting Check back the Surveillance Device VerificationCheck Snapshot of the Surveillance Device
Related manuals
Manual 38 pages 38.84 Kb