VBrick Systems VB4000, VB6000, VB5000 manual Set the IP Address with the Remote Control

Page 13

Appliance Setup

If you want to configure a static IP address, you must do it while the unit is operating in limited run mode. You cannot access the appliance while it is searching for DHCP server. You can set a static IP address with the Remote Control or with HyperTerminal as explained below.

3.If DHCP is successful, the monitor (MPEG appliances only) will display the VBrick logo in the lower right corner, and audio and video will be present. If the DHCP server supplies the Gateway IP Address or DNS server address, these parameters will replace the user-entered Gateway and DNS settings. If the DHCP server does not provide Gateway information, and if a Gateway is required for your network, you will need to

manually enter a Gateway IP Address.

TTo configure a gateway with the remote control:

1.Enter a Subnet Mask and press Select.

2.Enter a Gateway IP Address (see note below) and press Select. The appliance will

reboot with the IP address, subnet mask, and gateway configured.

3.MPEG appliances only. Connect the VBrick to another VBrick over the network using an Ethernet switch. For unicast, the destination IP Address of the encoding VBrick should be the IP Address of the decoding VBrick. Make sure the respective destination and receive ports also match.

Note If the DHCP server supplies the Gateway Address or DNS server address, these parameters will replace any user-entered Gateway and DNS settings. If the DHCP server does not provide Gateway information, and if a Gateway is required for your network, you will need to enter it manually.

Set the IP Address with the Remote Control

As noted, VBrick WM Appliances are shipped with a factory default address of 172.17.5.5. If necessary, you can change this IP address using the handheld IR Remote control. Remember that you cannot have multiple VBricks with the same IP address. Use the * button for the decimal point and the Left and Right buttons to erase.

TTo set the IP Address with the IR Remote control:

1.Aim the remote control at the IR port on the front panel and press Local Edit. The display on the front panel of the VBrick will request the password.

2.Press 23646 ("admin" numerically) and press Select on the remote control.

3.If the network is DHCP-capable and you want the network to select an IP address, press "Y" and then press Select. The VBrick will reboot and obtain an IP address. Otherwise press Select to continue.

4.Enter desired IP address. (Use the * button for the decimal point and the left/right buttons to erase characters entered by mistake.)

5.When done, press Select. If the remaining settings do not need to be modified press

Select again.

6.If the IP, subnet mask or gateway addresses have been modified and there are no errors, the VBrick will reboot.

Set the IP Address with HyperTerminal

TTo set the IP Address with HyperTerminal:

1.Connect an ASCII terminal (e.g. HyperTerminal, shipped with Windows 95/98/2000/ NT/XP) from the RJ-45 serial port (COM2) on the rear of the VBrick to the COM port

VBrick Appliance Getting Started Guide

5

Image 13
Contents VB4000-5000-6000 Series Network Video Appliances Copyright Contents Command Line Interface Using the IR RemoteIntegrated Web Server Index VB6000 ReferenceContents For More Information OrganizationFont Conventions Getting HelpPrinter-Friendly Topics in this chapter Setup OverviewCOM Using the Quick Start GuideConnect Output to a Video Monitor Appliance SetupConnect an Audio/Video Input Source Connect to the IP Network Power-on the ApplianceSet the IP Address Get the IP Address from a Dhcp ServerSet the IP Address with HyperTerminal Set the IP Address with the Remote ControlVerify Operation Install StreamPlayer PlusVerify Mpeg 4 Operation Verify Mpeg 2 OperationVerify WM Operation StreamPlayer Plus Overview Installing a System UpgradePassword button VBrick Tool Description Management ToolsVBDirectory Front Panel EditManagement Tools Simple Network Management Protocol TelnetVBrick SDK VBrick Systems, Inc Video Basics Understanding I, B, P Frames, Delay, and SynchronizationMPEG-2 Encoder Compression Reference Distance Group of Pictures GOPInterrelationship GOP Length N Reference Frame Distance MPEG-2 DelayMPEG-2 Audio Receiver Sensitivity Transmit PowerMPEG-4 Encoder Compression MPEG-4 AudioGetting the Best Video Video Resolution IP Address Configuration using Host NamesNetwork Considerations Assigning Multicast AddressesPriority Level Type of Service IP Differentiated Services DiffservVBrick Video Stream Handling Typical ApplicationsNetwork Jitter Ethernet IPOne-Way Broadcast and Desktop Streaming Two-Way Interactive Conferencing Serial Port Passthrough VBrick AccessoriesHow Passthrough Works Serial Port Passthrough Using Telnet Billboard Mpeg FeaturesPicture-in-Picture Embedded Web BrowserWM Features VBrick Systems, Inc Integrated Web Server Using IWSUser Level Default User Name Default Password Privileges LoginWelcome Screen Option Description Menu OptionsMaking Changes View ModeEdit Mode RebootingLogout Using Apply, Revert, and DefaultsMultiple Applies Serving Custom ASX and Html FilesVBrick Systems, Inc Key Description Front Panel EditDialog Window Description Error Message DescriptionMPEG-2/MPEG-4 Remote Control Controlling a VBStar Button Description Picture In Picture Controlling VBrick FeaturesBillboard Icon DescriptionConference Guide Program Guide WM Remote ControlConnection Modes Connecting with HyperTerminalConnecting with Telnet MIB-Based Command Line Interface Finding VBrick Parameters Command ResponseUsing a MIB Browser Setting VBrick ParametersLogging Using Get/Set Table Commands Using Get/Set Variable CommandsBeginning or Ending an Edit Session VBrick Stab vbrickSlot1EncoderHttpPushEnable.3=2 Applying Changes Error HandlingSaving Changes Example 1 Set Variable CLI ExamplesExample 3 Set Multiple Variables Example 2 Get VariableExample 4 Get Table Variables Example 5 Set Table VariablesCLI Sample Script Forever Menu-Based Command Line Interface Setting and Changing Parameters Editing Configuration ParametersSelecting Parenthetical Items Setting System Date and TimeOther Editing Keys Using SpacesVB6000 VBrick Appliance ModelsSeries Encoder Models Series Decoder ModelsExpanded Vbssm Activity LED VB6000 Expanded VbssmSequence Color Description RS-232/422/485 COM Port Pinouts Device InterfacesSolid. Indicates no Video In otherwise the LED is off Pin Function DirectionPower Out Exit Interface Power In Entry InterfaceEthernet Port Video-In and Video-Out CompositeAudioMate Video-In and Video-Out S-Video InterfaceAudio In and Audio Out Pin Description TypeVpp Balanced Relay Port Activity LED Event TriggeringChange RTS/DTR Control to Force On and click Apply VBrick Systems, Inc Index Index
Related manuals