5.End the edit session.
VBrick> SVAR vbrickEditName=
Example 2 – Get Variable
TTo check Slot1 Transmit state:
1.Login to the appliance.
2.Get the parameter.
GVAR vbrickSlot1EncoderNetworkTransmitEnable
$!vbrickSlot1EncoderNetworkTransmitEnable=2
Example 3 – Set Multiple Variables
TTo change Slot2 Receive IP and Port:
1.Login to the appliance.
2.Start an edit session.
3.Make your changes.
SVAR vbrickSlot2DecoderNetworkReceiveIpAddr=239.16.129.102
$!vbrickSlot2DecoderNetworkReceiveIpAddr=239.16.129.102
SVAR vbrickSlot2DecoderNetworkReceivePort=4444
$!vbrickSlot2DecoderNetworkReceivePort=4444
SVAR vbrickSlot2DecoderNetworkApplySet=2
$!vbrickSlot2DecoderNetworkApplySet=2
4.End the edit session.
Example 4 – Get Table Variables
TTo get Restart Table row 1:
1.Login to the appliance.
2.Get the parameters.
GTAB vbrickSysRestartInfoStartTime.1
$!vbrickSysRestartInfoStartTime.1=11/02/2006 08:35:27
GTAB vbrickSysRestartInfoStopTime.1
$!vbrickSysRestartInfoStopTime.1=11/02/2006 08:37:36
GTAB vbrickSysRestartInfoUpTime.1
$!vbrickSysRestartInfoUpTime.1=00:000 00:02
GTAB vbrickSysRestartInfoRestartType.1
$!vbrickSysRestartInfoRestartType.1=POWER
Example 5 – Set Table Variables
TTo set Http Push Table row 1:
1.Login to the appliance.
2.Start an edit session.
3.Make your changes.
STAB vbrickSlot1EncoderHttpPushUserName.1=BillOne
$!vbrickSlot1EncoderHttpPushUserName.1=BillOne
STAB vbrickSlot1EncoderHttpPushPassword.1=pass24
$!vbrickSlot1EncoderHttpPushPassword.1=pass24
58 | © 2008 VBrick Systems, Inc. |