Xantrex Technology PH1800 2 Possible Problems if Utility Power is Not Available, Probable Cause

Models: PH1800

1 64
Download 64 pages 61.71 Kb
Page 42
Image 42
Make sure the unit is connected to a 12 V

Troubleshooting

Table 3-2Possible Problems if Utility Power is Not Available

Problem

Probable Cause

Solution

 

 

 

Display is ON, AC is not

Low input voltage

Recharge the battery; check the

available on both

(error code E01)

connections and cable.

hardwired and unit

 

 

AC socket.

High input voltage

Make sure the unit is connected to a 12 V

 

(error code E02)

battery. Check battery is not overcharged.

 

Unit is overload protected

Reduce the amount of loads connected to

 

(error code E03)

the unit or the start up surge on the load

 

 

exceed surge limit of the unit.

 

Unit is thermal protected

Allow the unit to cool off. Reduce the

 

(error code E04)

load if continuous operation is required.

 

 

Improve ventilation. Make sure the

 

 

inverter's ventilation openings are not

 

 

obstructed.

 

 

Reduce the ambient temperature.

 

Unit is ground fault protected

Turn the unit off. Check all DC Input

 

(error code E09)

connections (PV, wind etc.) and repair

 

 

any faults or damage. Replace the ground

 

 

fault fuse (see page 3–10) and restart the

 

 

unit

 

 

 

Digital display or LED is

Display is normal

N/A

flickering especially in a

 

 

dark environment.

 

 

 

 

 

Inadequate run time.

Internal battery is not fully

Charge the internal battery by leaving the

 

charged.

charger backup power system plugged

 

 

into a wall outlet at least 20 hours.

 

Internal battery has aged past its

Replace the internal battery. The internal

 

warranted shelf life, the available

battery also ages prematurely if the

 

run time decreases.

system is installed in a hot environment.

 

 

 

Products connected to unit

Products connected to backup

Your application is not compatible with

malfunction or overheat.

power system do not accept

backup power system modified sine wave

 

modified sine wave form.

output.

 

 

See “Rechargeable Devices” on page 3–9.

 

 

 

3–6

975-0288-01-01

Page 42
Image 42
Xantrex Technology PH1800 manual 2 Possible Problems if Utility Power is Not Available, Probable Cause, Solution