Safety

If hardwired...... To Power Down the PowerHub 1800:

WARNING: Shock Hazard

If no DC Disconnect is used, then the DC input generators (solar or wind) will have to be physically disconnected to ensure power is OFF.

1

Disconnect any loads directly connected to the front panel of the PowerHub

2

Disconnect Loads connected to the PowerHub through AC Distribution Panel (Sub-panel) by opening the Inverter Output Circuit Breaker.

3Press ON/OFF Switch to turn OFF Inverter/Charger

5Disconnect the Utility power by opening the AC input circuit breaker in the main panel.

4

Disconnect the

DC Input.(s)

Disconnect the Battery Box(es)

6from the Inverter

Figure iii Power Down Procedure for Hardwired Installations

x

975-0288-01-01

Page 12
Image 12
Xantrex Technology PH1800 manual If hardwired...... To Power Down the PowerHub