Xantrex Technology PH1800 manual Changing Charging Settings

Models: PH1800

1 64
Download 64 pages 61.71 Kb
Page 33
Image 33
Changing Charging Settings

Basic Operation

Changing Charging Settings

Default Setting

The PowerHub 1800 is set at the factory to default to the 40 A Charging

 

Profile. In the event that one of the other profiles are required, follow the

 

instructions below to change the setting.

Setting the

To set the selection to the desired profile, stop pressing the Select Button

Selection

when the desired profile is displayed. The unit will set the profile shown

 

in the display, then will return to the default screen within 10 seconds.

Returns to

The charging setting will revert to the 40 A default setting whenever the

Default

ON/OFF Button is pressed or all DC input sources are removed and utility

 

AC is not available.

Press and hold for approximately

Display shows default

3-5 seconds.

charge setting (40A)

The AC LED will start to flash.

 

Press again within 10 seconds.

The Charge Setting changes

 

to the 10 A profile.

The Charge Setting changes to the

Press again within 10 seconds. 0 A profile. This profile completely turns off the charging feature.

Figure 2-5Input Displays

975-0288-01-01

2–9

Page 33
Image 33
Xantrex Technology PH1800 manual Changing Charging Settings