Specifications
10-amp Charging Profile
Table
Table A-6 10-amp Charging Profile
Parameter Name | Default Value |
|
|
Charger Setting | 10 A |
Maximum Bypass Current | 1200 W (10 A) |
Bulk Mode | 10 A |
Absorption Mode | 14.2 Vdc (4 hours maximum) |
Float Mode | 13.7 Vdc (8 hours) |
Switches from Absorption to | 4 A |
Float Mode |
|
Switches from Float Mode | 6 A |
back to Bulk Mode within the |
|
| |
current increases to 6 A. |
|
Standby Mode (Off Mode) | 12.5 Vdc |
Estimated charging time | 32 hours based on a single battery box with |
| two 100 Ah, 12 Vdc batteries and no other DC |
| charging sources |
|
|
0-amp Charging Profile
When Charger Setting 0 A is selected, the Battery Charger is disabled and will not charge the batteries. Use this mode if other DC charging sources are available or if it is necessary to temporarily disconnect the AC charging system.