Furuno FR-8111, FR-8251 DANGER! - High Voltage, Problem, Check point and probable, Remedy, cause

Models: FR-8111

1 69
Download 69 pages 21.49 Kb
Page 55
Image 55

Problem

Check point and probable

Remedy

 

cause

 

 

 

 

 

 

 

Adjust GAIN control

1.

IF amplifier

1.

Replace IF amplifier.

with A/C SEA control

2.

Signal cable between

2.

Check continuity and isolation of

set at minimum. Marks

 

antenna and display

 

coaxial cable. (Note: Disconnect the

and legends appear but

3.

Video Amplifier Circuit

 

plug and lugs at both ends of coaxial

no noise or echo.

 

 

 

cable before checking it by

 

 

 

 

ohmmeter.)

 

 

 

3.

Check video coax line for secure

 

 

 

 

connection. If connection is good,

 

 

 

 

replace SPU Board.

 

 

 

 

 

Marks, legends and

1.

Magnetron

1.

Check magnetron current.

noise appear but no

2.

Modulator Board

 

Replace magnetron.

echo. (Transmission

3.

Modulator SCR

2.

Replace Modulator Board.

leak, representing own

4.

SPU Board

3.

Replace SCR.

ship position, is

 

 

 

DANGER! - High Voltage

absent.)

 

 

4.

Replace SPU Board.

 

 

 

 

 

 

 

 

Picture not updated

1.

Bearing Signal Generator

1.

Check the connection of signal cable.

 

 

Board (antenna unit)

2.

Replace SPU Board.

 

2.

SPU Board

3.

Turn off and on radar.

 

3.

Video lockup

 

 

 

 

 

 

 

Incorrect orientation of

1.

SPU Board

1.

The HDG readout shows xxx.x when

picture

2.

Gyro Interface

 

heading signal is not received.

 

 

 

2.

Replace gyro interface.

 

 

 

 

 

TUNE control adjusted

1.

Deteriorated magnetron

1.

With radar transmitting on 48 mm

but poor sensitivity

2.

Detuned MIC

 

range, check magnetron

 

3.

Dirt on radiator face

 

current. If current is below normal

 

4.

Water ingress to the

 

value, magnetron may be

 

 

waveguide or other feeder

 

defective. Replace magnetron.

 

 

line.

2.

Check MIC detecting current. If it is

 

5.

Second trace rejection is ON.

 

below normal value, MIC may have

 

 

 

 

become detuned. MIC must be tuned.

 

 

 

3.

Clean radiator surface.

 

 

 

4.

Remove water from the feeder line.

 

 

 

5.

Disable the second-trace rejector

 

 

 

 

referring to paragraph 1.31.

 

 

 

 

 

Range changed but no

1.

Defective RANGE key

1.

Try to hit [+] and [-] RANGE keys

radar picture change

2.

SPU Board

 

several times. If unsuccessful,

 

3.

Video lockup

 

replacement of keypad may be

 

 

 

 

required.

 

 

 

2.

Replace SPU Board.

 

 

 

3.

Turn off and on radar.

 

 

 

 

 

4 – 3