Installation

Caution: Installation of the MCPB requires removal of equipment covers, exposing the risk of electrical shock. Unauthorized modification can also void the warranty. For this reason, installation should be performed by quali- fied service individuals only.

Accessory Connector

An Accessory connector (included with the MCPB) must be installed in the MCP35A prior to interconnecting these two units. Refer to Figure 6 and the following instructions.

1. Remove the top cover of the MCP35A.

2.Insert the accessory connector in the rear panel cutout marked ACCESSORY.

3.Remove the existing connectors from J10 and J14.

4.Push the female connectors on the accessory cable onto the terminal pins of J10, J11, and J14, as shown in Figure 6.

5.Replace the top cover.

Figure 6 - Wiring Diagram, Installation of Accessory Connector in MCP35A

Interconnections

Refer to Figure 7.

1. Connect the male 6-pin cable connector, labeled ACCESSORY, on the MCPB to the female 6-pin connector, labeled ACCESSORY, on the MCP35A.

2.Connect the male 9-pin cable connector, labeled SWITCHBANK, on the top of the MCPB, to the 9-pin female connector, labeled TO SWITCHBANK, on the MCP35A .

3.Connect the male 12-pin connector from the SBA325 switchbank to the 12-pin female connector on the MCPB labeled TO SWITCHBANK.

4.Connect the MCPB Line Out to the Hi-Z Input of the Channel B amplifier.

5.Connect the 25V output of the amplifier to the 25V input on the MCPB.

10

Image 10
Contents Multi-Graphic Mcpb & Series 115B, 2223R, & 2233R Important Safety Information Contents Series 115B System DescriptionsSeries 2223R & 2233R LPC4 Loop Priority Control Option OptionsMCP-EXP Input Expander Option CPP Handset Communication Option ASF4 Alarm-Signaling OptionPBA3 Push-Button Alarm Panel Option Receiving a Call From a Staff StationCalling a Staff Location Calls Between Staff StationsSCT Six-Circuit Time Signaling Option Wiring Diagram, SCT Six-Circuit Time Signalling FeatureTWK351 and TWK354 Two-Wire Call-in Options Mcpb Program Control PanelAccessory Connector InstallationInterconnections Phantom Power Technical SpecificationsMIC1 Monitor Mute Limited Warranty Exclusion of Certain Damages