Bogen 115B, 2233R, 2223R, MCPB user manual Calling a Staff Location, Calls Between Staff Stations

Page 7

3.When a conversation is finished, press the ON/OFF switch to release it. Note that if both parties hang up before the TPS4 is turned off, the red DISCONNECT LED will illuminate and the call-in tone will sound (returning the switch to the OFF position will extinguish both). Return the room selector switch to OFF or intercom communica- tion will resume.

Calling a Staff Location

1. Press the ON/OFF switch on the TPS4 and pick up the console handset. Select the station to be called by placing the appropriate switch on the room selector panel in the “C” position.

2.Call the staff location by pressing the CALL button, which sends a call tone to the station loudspeaker. Wait for the other party to respond by picking up the handset.

3.When the conversation is finished, follow step 3 under Receiving a Call From a Staff Station.

NOTE: Alternate Method - Call the station using the INTERCOM function of the MCP35A, then follow steps 2 and 3, under Receiving a Call From a Staff Station (page 6).

Calls Between Staff Stations

Two staff stations can communicate privately after being connected by the operator at the console (place each room selector switch in the “C” position). The console operator may leave the conversation by hanging up the handset. As long as the two staff handsets are off hook, the green IN-USE LED will illuminate. When the handsets are returned to the switch hook, the DISCONNECT LED will illuminate, and the Call-In Tone will sound at the MCP35A. At this point the operator resets both the room selector panel switches to OFF and presses the ON/OFF switch on the TPS4 to release it.

Figure 3 - Wiring Diagram, CPP Handset Communication Feature

7

Image 7
Contents Multi-Graphic Mcpb & Series 115B, 2223R, & 2233R Important Safety Information Contents Series 115B System DescriptionsSeries 2223R & 2233R LPC4 Loop Priority Control Option OptionsMCP-EXP Input Expander Option Receiving a Call From a Staff Station ASF4 Alarm-Signaling OptionPBA3 Push-Button Alarm Panel Option CPP Handset Communication OptionCalls Between Staff Stations Calling a Staff LocationWiring Diagram, SCT Six-Circuit Time Signalling Feature SCT Six-Circuit Time Signaling OptionMcpb Program Control Panel TWK351 and TWK354 Two-Wire Call-in OptionsAccessory Connector InstallationInterconnections Phantom Power Technical SpecificationsMIC1 Monitor Mute Limited Warranty Exclusion of Certain Damages