ASF4 Alarm-Signaling Option

The ASF4 option provides four distinct tones for use as a manually-operated class change or for alarm signaling pur- poses (slow whoop, chime, steady, and interrupted tone). Tones are activated by remote contact closure. (Note: If the MCP35A built-in tone signal generator is not used for time signaling, it can be used as a single-tone alarm and would require only a remote contact closure.) Refer to Figure 2.

PBA3 Push-Button Alarm Panel Option

The PBA3 Alarm Panel is used with the ASF4 feature to provide activation of three separate alarm signals and includes a reset button. Refer to Figure 2.

Figure 2 - Wiring Diagram, ASF4 Alarm Signaling with PBA3

CPP Handset Communication Option

The CPP option uses the Bogen TPS4 panel to provide for control center-to-classroom and classroom-to-classroom phone communications. The TPS4 includes: an ON/OFF switch, which disconnects the intercom function of the MCP35A to allow private telephone conversations; a CALL button which transmits a call tone to selected speakers; an IN-USE LED, which illuminates when handsets are in use; and a disconnect function, which illuminates an LED and sounds a tone when all handsets are on-hook. Requires the Model HS201C or HS202C staff classroom phone and Model HS201C phone at the console. Refer to Figure 3.

Connections

Two terminal strips are included to connect the HS201C telephone handset and power supply. Connect the HS201C to the terminal strip labeled HS-20 and GND. Connect a power supply to the terminals labeled +12V and GND. Be sure to observe polarity.

Operation

Receiving a Call From a Staff Station

1. When the call-in switch at a staff location is activated, the corresponding LED on the room selector panel will illuminate and a tone will sound. Answer the call according to the instructions printed on the MCP35A under

INTERCOM.

2.To speak over handsets, instruct the staff location to pick up the handset. Then pick up the console handset and press the ON/OFF switch on the TPS4 (suspends normal intercom communication). The green IN-USE LED will illuminate.

6

Image 6
Contents Multi-Graphic Mcpb & Series 115B, 2223R, & 2233R Important Safety Information Contents System Descriptions Series 115BSeries 2223R & 2233R Options LPC4 Loop Priority Control OptionMCP-EXP Input Expander Option CPP Handset Communication Option ASF4 Alarm-Signaling OptionPBA3 Push-Button Alarm Panel Option Receiving a Call From a Staff StationCalling a Staff Location Calls Between Staff StationsSCT Six-Circuit Time Signaling Option Wiring Diagram, SCT Six-Circuit Time Signalling FeatureTWK351 and TWK354 Two-Wire Call-in Options Mcpb Program Control PanelInstallation Accessory ConnectorInterconnections Technical Specifications Phantom PowerMIC1 Monitor Mute Limited Warranty Exclusion of Certain Damages