Bogen 2223R, 2233R, MCPB Mcpb Program Control Panel, TWK351 and TWK354 Two-Wire Call-in Options

Page 9

TWK351 and TWK354 Two-Wire Call-in Options

The TWK351 (Series 115B, 2223R) and TWK354 (Series 2233R) are used only with the CA10A Call-in Switches to allow light annunciated call-in with 2-conductor shielded cable. Refer to Figure 5.

Note: Do not use SCR25A with 2-wire call-in. Refer to MP35A Installation Manual.

Figure 5 - Wiring Diagram, 2-Wire Call-In Modification

MCPB Program Control Panel

The Bogen Model MCPB is a program control panel designed to operate with Bogen Series 2233R Centralized School Sound Systems. It includes input and pre-amplification facilities, as well as monitoring control for a separately amplified program channel (Channel B). The panel interfaces with the Bogen Model MCP35A Master Control Panel (which provides the Channel A program facilities and MCPB power supply), the SBA325 room selector and annunci- ator panels (used to place selected speakers on the A or B program busses, or select intercom function) and a sep- arate Channel B program amplifier.

The MCPB includes inputs for two Lo-Z microphones and an auxiliary program source (e.g., CD player/receiver). Rear panel mounted input gain controls are provided to adjust the input level of each source. Phantom power is available for the microphone inputs, selectable with a printed circuit board jumper (see page 11).

Selection of the Channel B program source is by simple push button operation, following the color-coded guide- lines. A two-position switch (MONITOR A/B) allows selective monitoring of either program channel through the built-in monitor speaker on the MCP35A control panel. A level control and LED meter are provided to adjust and visually monitor the level.

A special All-Call feature overrides the Channel B bus when the MCP35A is used to make emergency announce- ments, telephone pages, or All-Call announcements.

Interconnection with the MCP35A, SBA325 room selector panels, and Channel B program amplifier are easily accomplished. The panel is finished to match the associated sound system equipment and uses only one rack space.

9

Image 9
Contents Multi-Graphic Mcpb & Series 115B, 2223R, & 2233R Important Safety Information Contents System Descriptions Series 115BSeries 2223R & 2233R Options LPC4 Loop Priority Control OptionMCP-EXP Input Expander Option PBA3 Push-Button Alarm Panel Option ASF4 Alarm-Signaling OptionCPP Handset Communication Option Receiving a Call From a Staff StationCalls Between Staff Stations Calling a Staff LocationWiring Diagram, SCT Six-Circuit Time Signalling Feature SCT Six-Circuit Time Signaling OptionMcpb Program Control Panel TWK351 and TWK354 Two-Wire Call-in OptionsInstallation Accessory ConnectorInterconnections Technical Specifications Phantom PowerMIC1 Monitor Mute Limited Warranty Exclusion of Certain Damages