SPECIAL APPLICATION
30.[LOCKFP]
This command locks or unlocks the front panel buttons. If locked, pressing the buttons on the front panel will have no effect on the
Command Format: [LOCKFPpCi]
p= Lock value (0 = OFF and 1 = ON) Ci = Unit ID (i = # from 0 to 99) Example:
Send the command [LOCKFP1] to lock the front panel of the
31.[ + ]
This command increments a selected property to be adjusted from the keyboard or front panel.
Command Format: [ + ] or [ +k ]
[+]= Increment level by
Select the brightness command for adjustment. The current brightness level is 24, but it is not the optimal value. After sending the following commands, an optimum level of 30 is obtained:
1.[BRIGHT]
The current brightness level is 24.
2. [+][+][+][+][+][+] or [ +6 ]
The level is now 30 and no further adjustments are required.
32.[ - ]
This command decrements a selected property to be adjusted from the keyboard or front panel.
Command Format: [ - ] or [
Example:
Select the brightness command for adjustment. The current brightness level is 24, but it is not the optimal value. After sending the following commands, an optimum level of 20 is obtained:
1.[BRIGHT]
The current brightness level is 24.
2.[ – ] [ – ] [ – ] [ – ] or [
The level is now 20 and is no further adjustments are required.
33.[…S]
This command allows a setting from a single command to be saved at one time. Use this command to save a single property where it is undesirable to save all the current settings.
Command Format: [ ..S]
S= Save
Example:
Set the brightness level to 20 and save this setting at the same time. In order to do this, send the command [BRIGHT20S].
34.[HELP]
This command displays information available for the
Command Format: [HELPCi]
Ci = Unit ID (i = # from 0 to 99)
Example:
In order to display the
14 |