Altinex AP445-401 manual Troubleshooting Guide

Page 16

SPECIAL APPLICATION

7.5 SUMMARY OF COMMANDS

1)

[SIDn]

Set ID number of the unit.

2)

[RSI]

Reset ID of the unit to 0.

3)

[RSN]

Return unit ID number.

4)

[VER]

Display firmware version.

5)

[C]

Display current status.

6)

[CnS]

Display/save current status.

7)

[STAT]

Display current status.

8)

[STATS]

Display/save current status.

9)

[CLR]

Retrieve default settings.

10)

[IN]

Select input.

11)

[INR]

Select input/recall settings.

12)

[MODER]

Select output resolution.

13)

[MUTE]

On-screen display ON/OFF.

14)

[VCR]

Toggle VCR/Standard mode.

15)

[BRIGHTn]

Set Brightness level.

16)

[BRIGHT]

Display/select Brightness.

17)

[CONTRn]

Set Contrast level.

18)

[CONTR]

Display/select Contrast.

19)

[COLORn]

Set Color level.

20)

[COLOR]

Display/select Color.

21)

[SHARPn]

Set Sharpness level.

22)

[SHARP]

Display/select Sharpness.

23)

[HUEn]

Set Hue level.

24)

[HUE]

Display/select Hue.

25)

[VLOA]

Set audio level.

26)

[SEL]

Adjust audio level.

27)

[MODEN]

Noise Reduction ON/OFF.

28)

[MODEA]

Aspect Ratio Wide/Standard.

29)

[FREEZ]

Freeze the displayed image

30)

[LOCKFP]

Lock front panel buttons.

31)

[ + ]

Increment by one.

 

32)

[ - ]

Decrement by one.

 

33)

[…S]

Save one parameter.

 

34)

[HELP]

Display RS-232 commands.

 

 

 

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied AP445-401. However, we would like to offer suggestions for the following:

8.1NO RESPONSE FROM PANEL Cause 1: The front panel is locked.

Solution: Connect to the AP445-401using standard RS-232 communication. Check the status [STAT] and verify the front panel is “Unlocked”. If there is still no response, please call Altinex at (714)-990-2300.

8.2 NO DISPLAY

Cause 1: The source has a problem.

Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.

Cause 2: The correct input is not selected.

Solution: Select the input type from the front panel or RS-232 bus. (See RS-232 accessible commands in Section 7). If no display is present, see Cause 3.

Cause 3: Cable connections are incorrect.

Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.

400-0422-001

15

Image 16
Contents AP445-401 Table of Contents Precautions / Safety Warnings Technical Specifications About Your AP445-401Description of AP445-401 Inputs ControlApplication Diagram Diagram 1 Typical ConfigurationDiagram 2 Internal View AP445-401 Block Diagram Audio SwitcherInstalling Your AP445-401 OperationFront Panel Operation Selecting the InputMaking Picture Adjustments Changing the Output ResolutionOutput Mode Resolution Adjusting the Volume Description of CommandsSIDn RSIRSN VERStat StatsCLR 10.Moder MuteVCR BRIGHTnContr COLORnColor SHARPnHUE VloaSEL ModenLockfp 31. +33. …S HelpTroubleshooting Guide Altinex Policy Limited WARRANTY/RETURN PolicyNo Sound