8)Connect the subwoofer amplifier to an AC power source; turn the unit ON. Measure the DC voltage at the “CD±” wires; it should be
9)If it is 25 volts or greater, turn the amplifier OFF, disconnect from the power source, and replace: IL120S, IL60: Q504,Q507 IRF640 on the Power Supply PCB, Infinity part# QM0015.
IL50, IL100s: Q1 IRF540 on the Power Supply PCB, Infinity part# QM0020.
10)If the voltage is normal, turn the amplifier OFF, disconnect from the power source, and reconnect the “CD±” leads.
11)Finish reassembling the amplifier, remount the heatsink, replace the amplifier in the cabinet and test the subwoofer.
20