Bogen PM-3000, PM-3180 manual Pswrd, Password

Page 40

Programming

Password

This function lets the installer change the program mode password.

1.Enter programming mode and press the NEXT or BACK buttons until PASSWORD appears on the display.

2. Press ENT to enter the function. The display shows the the cur- rent 3-digit password (The default is 0 0 0.) The first numeral will be flashing.

3. Press the NEXT or BACK but- tons to increment the first numer- al from 0 to 9.

4.Press ENT to store the selection.

PSWRD 000

5.The second numeral flashes. Repeat steps 3 and 4.

6.The third numeral flashes. Repeat steps 3 and 4 for the third numeral.

After entering the third numeral, the first numeral will begin to flash again. You can go through the digits as many times as you wish or you can exit this function and save the currently displayed password.

Note: Make sure to press ENT for each changed digit before exiting otherwise the original digit will remain, resulting in a password different from the one planned.

Note: If you forget the password, enter the number 4 5 7 for the password. This will send you directly to the password setting function. You can then change the password or simply read it to refresh your memory. When you exit this function, you auto- matically return to the user mode. Do not use 4 5 7 as a pass- word since you will not be given access to the rest of the menu features when using this number.

35

Image 40
Contents User’s guide Models PM-3000 & PM-3180 User’s Guide Publication No July Owner’s Information Contents Accessories UnpackingPacking List ConventionsIntroduction DescriptionFeatures ProMatrix units have the following featuresPM-3180 has these additional features PM-3000 includesInstall Control Panel Quick StartTo mount the control panel in a remote location Fan Outlet PM-3180 only Do Not BlockBasic Wiring Factory Programmed Configuration Microphone Feature Default OptionsInput Priority Level = highest, 6 = lowestTo Apply Power to the Unit Basic OperationUnderstanding the Control Panel To Select an Amp or Preamplifier ChannelTo Control Volume To Control Bass or TrebleTo Select a Specific Input To Return to Auto SwitchingTo identify which amplifier is under manual control Aux Input Trim Adjustment Important Operational NotesRear Panel Model PM-3000 Rear Panel Model PM-3180 Auxa Infrared Remote Controller Wiring Information Outputs For PM-3000 PreamplifierOutputs For PM-3180 Amplifier AUX Inputs Audio Process Link Wiring PM-3180 OnlyAux Input Trim Controls MIC Inputs Mic aMic B Mic B/TelTo Apply Power to the ProMatrix Unit User OperationProMatrix Control Panel To Select an Amp/ChannelTo Control Volume, Bass or Treble To Return to Auto Switching Important Operational NotesEnter Programming Mode ProgrammingDefaults Programming MenuA1/AUXA AssignmentProgramming Prec VOX Mic Set UpTo Set MIC Parameters ALC on PPS OFF IN-MICPress ENT to store the selection Press ENT to store the selecPresets Remember to press ENT after setting each level A1/AUX A-0Volume Limit A1/AUXAProgramming A1/VOL OFF InhibitAux Mute A1 LNK Amplifier Link PM-3180 OnlyPassword PswrdAuxa LabelsFactory Defaults CLR ALL noSure no Press ENT to confirm the selectionTesting & Troubleshooting TestingTroubleshooting No control over volume or tone Forgot passwordMic never active Mic distortedGetting Help Specifications PM-3180PM-3000 Spring Street Ramsey, NJ

PM-3000, PM-3180 specifications

The Bogen PM-3180 and PM-3000 are two powerful audio amplifiers designed to meet the diverse needs of various sound reinforcement applications, from commercial settings to large outdoor events. Both models are part of Bogen’s esteemed product lineup, known for their reliability, performance, and quality sound.

The Bogen PM-3180 is a high-performance amplifier capable of delivering up to 180 watts of power. It is designed for both commercial and institutional uses, featuring a versatile range of functionality. One of its significant attributes is the built-in mixing capabilities, allowing users to connect multiple audio sources effortlessly. With its broad frequency response and low total harmonic distortion, the PM-3180 ensures clear and robust audio output, making it suitable for music and speech applications alike.

In terms of connectivity, the PM-3180 offers various inputs, including balanced microphone inputs and unbalanced line inputs, catering to different audio source configurations. Its integral priority system allows for automatic switching in case of emergency announcements, ensuring critical communications get through without interruption. While operating, the PM-3180 remains energy-efficient, equipped with features that minimize power consumption while maximizing output.

On the other hand, the Bogen PM-3000 serves as an excellent companion for those with slightly lower power requirements, offering up to 150 watts of output. Its compact design makes it an ideal choice for applications where space is limited. Despite its size, the PM-3000 does not compromise on audio quality, delivering clean and distortion-free sound for various environments, such as classrooms, meeting rooms, and small events.

Both amplifiers utilize modern technology to ensure durability and performance. They incorporate advanced thermal protection, preventing overheating during extended use. Additionally, the PM-3000 includes a built-in LED power indicator that provides a visual cue of operational status. Both models are designed for easy installation and maintenance, featuring a user-friendly interface that simplifies adjustments and configuration.

In summary, the Bogen PM-3180 and PM-3000 amplifiers stand out for their exceptional features, performance-oriented design, and enduring reliability. Whether you're managing a school event, a business presentation, or a public address system, these amplifiers are equipped to deliver high-quality sound that meets your needs, backed by Bogen's longstanding reputation in the audio industry.