Bogen PM-3180, PM-3000 manual Auxa, Labels

Page 41

Programming

Labels

This function lets you modify the names displayed for the current input source during user operation. For example, you can change the name of AUX A to TAPE.

1.Enter programming mode and press the NEXT or BACK buttons until LABELS appears on the display.

2.Press ENT to enter the function.

 

The display shows AUXA or a pre-

AUXA

 

 

 

viously entered label. The first

 

 

character will be flashing.

 

3.

If desired, select another input by

 

 

pressing the appropriate button.

 

4.

Press the NEXT or BACK but-

 

 

tons to scroll through the avail-

 

 

able characters (A-Z, 0-9, —, [space]) and stop at the desired character.

5.Press ENT to store the letter selection. The PROG light will blink to indicate that data was stored.

6.The second character position flashes. Repeat Steps 4 and 5.

7.The third character position will flash and so on. Repeat steps 4 and 5 for each letter in turn, to a maximum of 10 characters.

Note: To edit a label press the ENT key to skip over character positions until the one you want to change is flashing. Press the NEXT or BACK buttons to change the character and then press ENT to save it.

8.When you have finished entering all the desired characters, press EXIT or select a different input.

9.Press EXIT to return to the function menu. At this point you can exit the programming mode or press NEXT or BACK to select another function.

36

Image 41
Contents User’s guide Models PM-3000 & PM-3180 User’s Guide Publication No July Owner’s Information Contents Unpacking AccessoriesPacking List ConventionsDescription IntroductionProMatrix units have the following features FeaturesPM-3180 has these additional features PM-3000 includesQuick Start Install Control PanelTo mount the control panel in a remote location Fan Outlet PM-3180 only Do Not BlockBasic Wiring Microphone Feature Default Options Factory Programmed ConfigurationInput Priority Level = highest, 6 = lowestBasic Operation To Apply Power to the UnitUnderstanding the Control Panel To Select an Amp or Preamplifier ChannelTo Control Bass or Treble To Control VolumeTo identify which amplifier is under manual control To Return to Auto SwitchingTo Select a Specific Input Important Operational Notes Aux Input Trim AdjustmentRear Panel Model PM-3000 Rear Panel Model PM-3180 Auxa Infrared Remote Controller Outputs For PM-3000 Preamplifier Wiring InformationOutputs For PM-3180 Amplifier Aux Input Trim Controls Audio Process Link Wiring PM-3180 OnlyAUX Inputs Mic a MIC InputsMic B Mic B/TelUser Operation To Apply Power to the ProMatrix UnitProMatrix Control Panel To Select an Amp/ChannelTo Control Volume, Bass or Treble Important Operational Notes To Return to Auto SwitchingProgramming Enter Programming ModeProgramming Menu DefaultsAssignment A1/AUXAProgramming To Set MIC Parameters Mic Set UpPrec VOX IN-MIC ALC on PPS OFFPress ENT to store the selection Press ENT to store the selecPresets A1/AUX A-0 Remember to press ENT after setting each levelA1/AUXA Volume LimitProgramming Inhibit A1/VOL OFFAux Mute Amplifier Link PM-3180 Only A1 LNKPswrd PasswordLabels AuxaCLR ALL no Factory DefaultsSure no Press ENT to confirm the selectionTesting Testing & TroubleshootingTroubleshooting Forgot password No control over volume or toneMic never active Mic distortedGetting Help PM-3180 SpecificationsPM-3000 Spring Street Ramsey, NJ

PM-3000, PM-3180 specifications

The Bogen PM-3180 and PM-3000 are two powerful audio amplifiers designed to meet the diverse needs of various sound reinforcement applications, from commercial settings to large outdoor events. Both models are part of Bogen’s esteemed product lineup, known for their reliability, performance, and quality sound.

The Bogen PM-3180 is a high-performance amplifier capable of delivering up to 180 watts of power. It is designed for both commercial and institutional uses, featuring a versatile range of functionality. One of its significant attributes is the built-in mixing capabilities, allowing users to connect multiple audio sources effortlessly. With its broad frequency response and low total harmonic distortion, the PM-3180 ensures clear and robust audio output, making it suitable for music and speech applications alike.

In terms of connectivity, the PM-3180 offers various inputs, including balanced microphone inputs and unbalanced line inputs, catering to different audio source configurations. Its integral priority system allows for automatic switching in case of emergency announcements, ensuring critical communications get through without interruption. While operating, the PM-3180 remains energy-efficient, equipped with features that minimize power consumption while maximizing output.

On the other hand, the Bogen PM-3000 serves as an excellent companion for those with slightly lower power requirements, offering up to 150 watts of output. Its compact design makes it an ideal choice for applications where space is limited. Despite its size, the PM-3000 does not compromise on audio quality, delivering clean and distortion-free sound for various environments, such as classrooms, meeting rooms, and small events.

Both amplifiers utilize modern technology to ensure durability and performance. They incorporate advanced thermal protection, preventing overheating during extended use. Additionally, the PM-3000 includes a built-in LED power indicator that provides a visual cue of operational status. Both models are designed for easy installation and maintenance, featuring a user-friendly interface that simplifies adjustments and configuration.

In summary, the Bogen PM-3180 and PM-3000 amplifiers stand out for their exceptional features, performance-oriented design, and enduring reliability. Whether you're managing a school event, a business presentation, or a public address system, these amplifiers are equipped to deliver high-quality sound that meets your needs, backed by Bogen's longstanding reputation in the audio industry.