Kathrein MSK 200/S2 Choosing the Channel to be Measured, Selecting the Desired Measurement

Page 14

OPERATION

CHOOSING THE CHANNEL TO BE MEASURED

Now one can choose the channel to be measured:

Generally there are different possibilities offered as to how a measurement channel can be chosen

1.Selection of programme through programme name

1.1.Press “Chan.Tab“ to select the desired channel table

1.2.Enter the desired programme name in the entry field “Prog.Name“ (the programme name is automati- cally completed)

2.Selection of programme through channel number

2.1.Press “Chan.Tab“ to select the desired channel table

2.2.Use “Prog.Number“ to enter the desired programme position

3.Selection of programme through channel

3.1.Press “Chan.Tab“ to select the desired channel table

3.2.The desired channel can be selected in the “Channel“ menu

4.Selection of programme through frequency

4.1.Press “Chan.Tab“ to select the desired channel table

4.2.The desired frequency can be set in the entry field “Frequency“

4.3The frequency entered is automatically corrected to the appropriate video carrier frequency or channel centre frequency. Use the “<“ and “>“ keys to fine-tune the frequency

If “Couple Chan“ is set to “TO STAND“ in the “PREFERENCES“ menu, all other parameters (Standard, Map- ping, Symbol Rate etc.) are automatically set. To set the parameters individually, go to the “PREFERENCES“ menu and change the setting “Couple Chan“ to “NOT COUP.“

SELECTING THE DESIRED MEASUREMENT

In order to carry out a measurement after one has successfully selected the desired channel, one now has to

select the required measurement instrument using the hard-key - the measurement instrument being selected from the list in the displayed on-screen menu.

The following measurements or measurement instruments can be selected:

Submenu for settings (preferences), channel list editing, DiSEqCTM etc.

Spectrum analyser

Constellation analyser

Impulse / Reflection measurement (exclusively for DVB-T)

Read in MPEG stream, MPEG monitor

Memory oscilloscope

Summary measurements, simultaneous measurement of RF signal level, S/N, MER, BER, HUM and video voltage

Display of video, video text display

Settings for diverse outputs (ASI, TS parallel, Video)

14

Image 14
Contents MSK 200/S2 Validity of this Manual General Safety InformationPREFACE/IMPORTANT Notes Content Safety Symbols used on Kathrein devices and in manualsSafety MSK 200/S2, Order no 75 Ω FEATURES/DELIVERY ScopeDelivery Scope MSK 200/S2, Order no 50 ΩInitial START-UP Setting UP the DeviceOperation SET-UP OptionsUsing the Device on the Shoulder Strap For right-handed users For left-handed usersHelp Function Setup Help LangGeneral Operation Keyboard OperationSource Analyze Touchscreen OperationSources General Operation General Operation Choice of the Signal Source and Measurement Choice of the Signal SourceChoosing the Channel to be Measured Selecting the Desired MeasurementConst Marker or SettingSpectrum ScopeFunction Overview Remote ControlSignalling OperationMeasurement Options Reception RangesDemodulation Saving Measured ValuesFunctions Technical AppendixDesign Type MSK 200/S2 Digital Catv receiver J83 A, B, C Connections Service Main Services Service936.3448/-/1008/ZWT Technical data subject to change