T101 | T104 |
INPUT 1 | INPUT 4 |
T102 | T103 |
INPUT 2 | INPUT 3 |
TO AMP_A | TO REMOTE CONTROL | TO AMP_B |
PCB 84167 | PCB 81330.2 | PCB 84167 |
Diagram 9 Printed circuit board 81330.1 with inserted input transformers NRS90208
10.INCORPORATION INTO 19" FLIGHTCASES OR 19" RACK SYSTEMS
Note Do not operate the DPA 4410 without its enclosure or without parts of the enclosure.
When incorporating the DPA 4410 into a 19" flightcase or 19" rack system make sure, that there is sufficient
Note For
11. FUSES
location | pos. | used for | value | dimensions | standard |
|
|
|
|
|
|
fuse switch (11) | F501 | mains fuse 230V~ AC | T4A 250V | 5 x 20 mm | IEC 127 |
fuse switch (11) | F501 | mains fuse 115V~ AC | T8A 250V | 5 x 20 mm | IEC 127 |
PCB 85264.2 | F502 | battery fuse 24V DC | 25A 32V | DIN | |
PCB 85264.2 | F503 | battery fuse 24V DC | 25A 32V | DIN | |
PCB 85264.2 | F504 | T6.3A 250V | 5 x 20 mm | IEC 127 | |
PCB 85264.2 | F505 | T6.3A 250V | 5 x 20 mm | IEC 127 | |
PCB 85264.2 | F506 | T6.3A 250V | 5 x 20 mm | IEC 127 | |
PCB 85264.2 | F507 | T6.3A 250V | 5 x 20 mm | IEC 127 |
28