Dynacord DPA 4410 dimensions Specifications of the DPA

Page 14

12.SPECIFICATIONS OF THE DPA 4410

Mains supply:

 

 

 

 

 

 

Voltage:

 

 

115 V / 230 V~ AC, ±10

 

Frequency:

 

 

50 - 60

 

 

Protection class:

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

mains supply

Umains [V]

Imains [A]

Pmains [VA]

Pmains [W]

Pout [W]

Pv [W]

 

 

 

 

 

 

 

 

 

floating

230

0.27

62

35

0

35

 

normal operation (-10 dB)

230

1.64

377

275

40

235

 

alert (-3 dB)

230

3.25

748

585

200

385

 

normal operation

230

4.39

1010

815

400

415

 

starting current

< 36 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains supply

Umains [V]

Imains [A]

Pmains [VA]

Pmains [W]

Pout [W]

Pv [W]

 

 

 

 

 

 

 

 

 

floating

115

0.54

62

35

0

35

 

normal operation (-10 dB)

115

3.28

377

275

40

235

 

alert (-3 dB)

115

6.50

748

585

200

385

 

normal operation

115

8.78

1010

815

400

415

 

starting current

< 20 A

 

 

 

 

 

Pmains [VA]=apparent power Umains*Imains, Pmains [W]=true power, Pout [W]=output power Pv [W]=leakage power

Battery supply:

 

 

 

 

 

Voltage:

 

 

24 V DC, -10/+30 %

 

 

 

 

 

 

 

 

 

battery supply

UB [V]

IB [A]

Pi [W]

Pout [W]

Pv [W]

 

 

 

 

 

 

 

 

floating

24

1.0

24

0

24

 

normal operation (-10 dB)

24

7.5

180

40

140

 

normal operation

24

18

432

250

182

 

starting current

< 3.9 A

 

 

 

 

Pi [W]=input power UB*IB, Pout [W]=output power, Pv [W]=leakage power

 

Input characteristics:

 

 

electronically balanced

 

Nominal input level

 

 

775 mV = 0 dBu / 10 kohms

 

Power output characteristics:

 

balanced, off ground potential

 

Nominal output power

 

 

 

 

 

 

with mains supply

 

 

4 x 100 W ( IEC 268-3)

 

Nominal output voltage

 

 

 

 

 

 

with mains supply

 

 

100 V (70 V / 50 V / 20 V)

 

Nominal load impedance

 

100 ohms (50 / 25 / 4 ohms)

 

minimal total impedance

 

 

 

 

 

 

 

 

 

 

 

 

 

100 W Output capacity

 

 

200 W Output capacity

 

 

 

 

 

 

 

 

100 V Output

100 Ohm / 250 nF

50 V + 50 V Output

50 Ohm / 500 nF

 

70 V Output

50 Ohm / 500 nF

———

———

 

 

50 V Output

25 Ohm / 1000 nF

———

———

 

 

20 V Output

4 Ohm/ 6250 nF

———

———

 

Noise voltage (A-weighted)

 

-56 dBu

 

 

THD at PA nominal

 

 

1 %

 

 

Overall frequency response

 

60 Hz … 20 kHz

 

Distortion-limited response

 

 

 

 

(PA nominal -3 dB, k= 1 %)

 

60 Hz … 5 kHz

 

Crosstalk between two channels

 

80 dB at 1 kHz / 60 dB at 10 kHz

30

Image 14
Contents DPA 4410 Power Amplifier FeaturesSafety Component has to be Replaced with Original Part only For US and Canada onlyINDICATORS, Controls and Connections Table of Contents General Notes Installation NotesPrecautions and Recommendations Amplifier has to be protected fromHinweis Outputs Power OutputInputs 1 Power Output with 100 V speaker systems Power Output with low impedance speaker systems100 W or 2 x 100 W + 1 x 200 W or 2 x 200 W Power Output 100 V with double output capacityRemote Control connection Monitor outputMetering DC OperationAdditional Functions and Features NRS 90206 pilot tone surveillanceNRS 90207 ground fault surveillance NRS 90208 input transformerIncorporation Into 19 Flightcases or 19 Rack Systems FusesPage Specifications of the DPA NRS 90207 ground fault surveillance module for four outputs Optional accessories for the DPASpecifications of the Optional Accessories NRS 90206 pilot tone surveillance module for four outputs