Dynacord DPA 4410 Optional accessories for the DPA, Specifications of the Optional Accessories

Page 15

Monitor output characteristics:

unbalanced

Nominal output voltage

2 V = +8.2 dBu

Nominal load impedance

600 ohms

Overall frequency response

60 Hz … 20 kHz

Environmental temperature

+5° C … +40° C

Technical regulations:

 

This appliance is in accordance

 

with the following regulations:

EN 50081-1, EN 50082-1, EN 60065

Dimensions (W x H x D)

19" (483 mm) x 3 HU (132 mm) x 345 mm

installation depth

 

without external connectors

340 mm

installation depth

 

with external connectors

max. 400 mm

Weight

22.3 kg

Colour

anthracite

Optional accessories for the DPA 4410:

NRS 90206 pilot tone surveillance module (for four outputs)

NRS 90207 ground fault surveillance module (for four outputs)

NRS 90208 balanced input transformer module (for one input)

13.SPECIFICATIONS OF THE OPTIONAL ACCESSORIES

13.1NRS 90206 pilot tone surveillance module (for four outputs)

Pilot tone frequency

19 kHz ±1 %

Error detection threshold

12 mV

Error message output

collective fault message with READY relay

13.2NRS 90207 ground fault surveillance module (for four outputs)

Input

speaker line 20 V / 50 V / 70 V / 100 V

Error message output

collective fault message with READY relay

Disruptive strength

1000 Veff

Error detection threshold

50 kohms

13.3NRS 90208 balanced input transformer module (for one input)

Response

20 Hz … 20 kHz

Input impedance

10 kohms

Floating transformation ratio

1:1

Primary winding resistance

1420 ohms at 20° C

Secondary winding resistance

1420 ohms at 20° C

31

Image 15
Contents Features DPA 4410 Power AmplifierFor US and Canada only Safety Component has to be Replaced with Original Part onlyINDICATORS, Controls and Connections Table of Contents Amplifier has to be protected from Installation NotesPrecautions and Recommendations General NotesOutputs Power Output Inputs 1Hinweis Power Output with low impedance speaker systems Power Output with 100 V speaker systemsMonitor output Power Output 100 V with double output capacityRemote Control connection 100 W or 2 x 100 W + 1 x 200 W or 2 x 200 WDC Operation MeteringNRS 90206 pilot tone surveillance Additional Functions and FeaturesNRS 90208 input transformer NRS 90207 ground fault surveillanceFuses Incorporation Into 19 Flightcases or 19 Rack SystemsPage Specifications of the DPA NRS 90206 pilot tone surveillance module for four outputs Optional accessories for the DPASpecifications of the Optional Accessories NRS 90207 ground fault surveillance module for four outputs