Monitor output characteristics: | unbalanced |
Nominal output voltage | 2 V = +8.2 dBu |
Nominal load impedance | 600 ohms |
Overall frequency response | 60 Hz … 20 kHz |
Environmental temperature | +5° C … +40° C |
Technical regulations: |
|
This appliance is in accordance |
|
with the following regulations: | EN |
Dimensions (W x H x D) | 19" (483 mm) x 3 HU (132 mm) x 345 mm |
installation depth |
|
without external connectors | 340 mm |
installation depth |
|
with external connectors | max. 400 mm |
Weight | 22.3 kg |
Colour | anthracite |
Optional accessories for the DPA 4410:
NRS 90206 pilot tone surveillance module (for four outputs)
NRS 90207 ground fault surveillance module (for four outputs)
NRS 90208 balanced input transformer module (for one input)
13.SPECIFICATIONS OF THE OPTIONAL ACCESSORIES
13.1NRS 90206 pilot tone surveillance module (for four outputs)
Pilot tone frequency | 19 kHz ±1 % |
Error detection threshold | ≤ 12 mV |
Error message output | collective fault message with READY relay |
13.2NRS 90207 ground fault surveillance module (for four outputs)
Input | speaker line 20 V / 50 V / 70 V / 100 V |
Error message output | collective fault message with READY relay |
Disruptive strength | 1000 Veff |
Error detection threshold | ≤ 50 kohms |
13.3NRS 90208 balanced input transformer module (for one input)
Response | 20 Hz … 20 kHz |
Input impedance | ≥ 10 kohms |
Floating transformation ratio | 1:1 |
Primary winding resistance | 1420 ohms at 20° C |
Secondary winding resistance | 1420 ohms at 20° C |
31