Extron electronic MTP 15 HD A manual Edid Configuration, Recording a Display Edid

Page 21

EDID Configuration

The MTP 15HD A transmitter can either record EDID from a display device, or a pre-programmed EDID can be selected using the rotary and DIP switches.

Recording a Display EDID

1.Turn the rotary switch to position 0.

NOTE: The vertical frequency DIP switch has no effect in this mode.

2.Connect the display device to the local monitor output connector.

NOTE: The MTP 15HD transmitter should be supplying the necessary 5 VDC to power on the display. However, to ensure that EDID is being transmitted, power on the display.

3.When ready to record to memory, press and release the recessed record button

(see C on page 6) to begin the recording process. The Record LED (see B on

page 6) will flash red rapidly during recording, then return to solid green after recording is completed. At this time, the display can be disconnected. Connect the source device to the input connector.

4.Power on or restart the source device if necessary.

Using a Pre-Programmed or User-Recorded EDID

1.If you have not already done so, connect the source device to the MTP 15HD transmitter. Do not power on the source device at this time.

2.Set the front panel DIP switch (see D on page 6) to the required frequency (50 or 60 Hz).

3.Set the rotary dial (see E on page 7) to the required position (see table below). Positions 1 through E are factory installed. Position 0 is for user-recorded EDID information. Position F passes the EDID from the display connected to the loop-out directly back to the input.

Rotary Switch

Resolution

Position

 

 

 

0

User-recorded EDID

 

 

1

800x600

 

 

2

1024x768 (default)

 

 

3

1280x720

 

 

4

1280x768

5

1280x800

 

 

6

1280x1024

 

 

7

1360x768

 

 

8

1366x768

 

 

9

1400x1050

A

1400x900

 

 

B

1600x1200

 

 

C

1680x1050

 

 

D

1920x1080

 

 

E

1920x1200

F

Local monitor pass-through

 

 

MTP 15HD A Series • Installation and Operation

16

Image 21
Contents MTP 15HD a Series User GuideSafety Instructions English Safety InstructionsRegistered Trademarks FCC Class a NoticeSpecifications Availability Conventions Used in this GuideNotifications Contents About this Guide IntroductionTwisted Pair Cable Advantages About the MTP Transmitters and ReceiversTransmission Distance Composite 800 1000 Video Installation Overview Installation OperationMTP 15HD Front Panels Front Panel FeaturesMTP 15HD a Series Installation and Operation MTP 15HD a Series Installation and Operation Transmitter Rear Panel Transmitter Rear Panel FeaturesMm Stereo Audio Plug Receiver Rear Panel Receiver Rear Panel FeaturesPotential damage to property Power Supply Wiring and GroundingPotential damage to property Twisted Pair Cable Termination Twisted Pair Cable Termination DiagramSkew Delay Compensation SEQ Receiver Skew CompensationNon-SEQ Receiver Skew Compensation Using a Pre-Programmed or User-Recorded Edid Edid ConfigurationRotary Switch Resolution Position Recording a Display EdidOptional Accessories Part Numbers, Optional Accessories, Cables, and ConnectorsReference Information Part NumbersConnectors RJ-45 ConnectorsCables Mounting Tabletop PlacementUnder Desk and Furniture Mounting Rack MountingRack Mounting Procedure Back of the Rack Mounting ProcedureProjector Mounting Extron Warranty