EDID Configuration
The MTP 15HD A transmitter can either record EDID from a display device, or a
Recording a Display EDID
1.Turn the rotary switch to position 0.
NOTE: The vertical frequency DIP switch has no effect in this mode.
2.Connect the display device to the local monitor output connector.
NOTE: The MTP 15HD transmitter should be supplying the necessary 5 VDC to power on the display. However, to ensure that EDID is being transmitted, power on the display.
3.When ready to record to memory, press and release the recessed record button
(see C on page 6) to begin the recording process. The Record LED (see B on
page 6) will flash red rapidly during recording, then return to solid green after recording is completed. At this time, the display can be disconnected. Connect the source device to the input connector.
4.Power on or restart the source device if necessary.
Using a Pre-Programmed or User-Recorded EDID
1.If you have not already done so, connect the source device to the MTP 15HD transmitter. Do not power on the source device at this time.
2.Set the front panel DIP switch (see D on page 6) to the required frequency (50 or 60 Hz).
3.Set the rotary dial (see E on page 7) to the required position (see table below). Positions 1 through E are factory installed. Position 0 is for
Rotary Switch | Resolution |
Position |
|
|
|
0 | |
|
|
1 | 800x600 |
|
|
2 | 1024x768 (default) |
|
|
3 | 1280x720 |
|
|
4 | 1280x768 |
5 | 1280x800 |
|
|
6 | 1280x1024 |
|
|
7 | 1360x768 |
|
|
8 | 1366x768 |
|
|
9 | 1400x1050 |
A | 1400x900 |
|
|
B | 1600x1200 |
|
|
C | 1680x1050 |
|
|
D | 1920x1080 |
|
|
E | 1920x1200 |
F | Local monitor |
|
|
MTP 15HD A Series • Installation and Operation | 16 |