1/2
Service Technical Information
MODEL NO.
TV− SA2151/A2118/A2110/A2018/A2010
SUBJECT
Distinction Switch setting up procedure
REF.No. :G − A0− 125− E0
DATE :10. APR. 2001
<CONTENTS>
Setup procedure for Distinction Switch was not described in the service manuals below.
TV− SA2151 | 09− 007− 420− 8S1 | |||
TV− A2110 / A2118 | 09− | 007− | 416− | 7S3 |
TV− A2010 / A2018 | 09− | 007− | 420− | 5S1 |
Please refer to the following procedure when setting Distinction Switches.
<COUNTERMEASURE>
1.Press TEST key of a Jig remote control and set to the AGING mode.
2.Press SYSTEM key of a jig remote control and set to the Distinction Switch mode.
3.Make sure the lower part in the upper row on the screen 1:KE 1 ∼ 8:SH4, are shown in red as the below table. If not press the numeric key to make the items in question become red.
| Model Name | Item | Key |
|
| TV− SA2151 | SH3 | 7 |
|
| TV− A2118 | SH2 | 6 |
|
| TV− A2110 | KE2 | 2 |
|
| TV− A2018 | SH2 | 6 |
|
| TV− A2010 | KE2 | 2 |
|
|
|
|
|
|
Fig.1 Items to be selected by model
1 | : K E 1 |
|
|
| 5 | : | S H 1 |
|
|
| ||||
2 | : K E 2 |
|
|
| 6 | : | S H 2 |
|
|
| ||||
3 | : I | N D O 1 |
| 7 | : | S H 3 |
| Red |
| |||||
4 : I | N D O 2 8 : | S H 4 |
|
|
| |||||||||
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A B C D E F | Address 0∼ F | ||
| 1 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 0 0 0 1 | Date | 0∼ F |
| 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 |
|
| |||||||||||
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A B C D E F | Address 10∼ 1F | ||
| 1 | 0 | 1 | 1 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 1 0 0 0 0 | Date | 10∼ F |
Fig.2 Screen shot on the distinction switch set up mode | (Example : TV− SA2151) |
4.Check to see if the data of address
CHANNEL UP/DOWN | Select appropriate data (selected data appear in red) |
VOLUME UP/DOWN | Change value (0 or 1) |
5.After data input and/or confirmation is completed, Press TEST key to go back to the AGING mode.
| G | R | Code No. | Access Code | Modified Ser. No. | Parts Schedule |
| − | − | − | − | − | − |
|
|
|
|
|
|
|