1/1
Service Technical Information
| MODEL NO. | SUFFIX |
|
| |
| TV−C2121 / A21T1 / A2126 | KERJ2C,KEJ2C |
|
| |
|
| / SHJ2C / SHJ2C |
|
| |
|
|
|
|
|
|
| SUBJECT |
|
|
|
|
| NO POWER |
|
| REF No :G − A 2 − 0 2 8 − E 0 | |
|
|
|
|
|
|
|
|
|
| DATE :0 5 . S E P . 2 0 0 2 | |
|
|
|
| ||
|
|
|
|
|
|
<SYMPTOM>
There may be a case of not turning on the power reason of DY coil defective.
<REPAIR>
1.Replace CRT Ass’y and Q601.
2.Making necessary adjustments (ex. White Balance, etc.) after replacing CRT. (Refer to the service manual)
Note. The below mentioned CRTs are pre−adjusted PURITY and CONVERGENCE.
<CAUTION>
Must discharge residual anode voltage before replacing CRT. If failed to do, there is a possibility to cause electric shock hazard. Refer to the service manual for discharging.
| Ref. | Parts Code | Description |
|
|
| Remarks | |||||
V901 | 8Z−JB9−611−010 | CRT,A51QAE320X45CQMA |
| TV−C2121(KERJ2C) | ||||||||
V901 | 8B−JAN−650−010 | CRT,A51QAE320X45CMMA(0,35) |
| TV−A21T1, TV−A2126, | ||||||||
|
|
|
|
|
|
|
|
|
| TV−C2121(KEJ2C) | ||
Q601 | 87−A30−633−010 | TR,2SD2627LS−YB |
|
|
| − | ||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
G |
| R |
| Code No. |
| Access Code |
| Modified Ser. No. |
| Parts Schedule | ||
− |
| − |
| − |
| − |
|
| − |
| − | |
|
|
|
|
|
|
|
|
|
|
|
|
|