1/1
Service Technical Information
| MODEL NO. | SUFFIX |
| TV− C143 / C148 / C1418 | KE,KER |
| TV− C208 / C203 / C2018 | SH,SHR |
|
|
|
SUBJECT
Remote controller does not works properly
REF.No. :G − A1− 057− E0
DATE :17. OCT. 2001
<CONTENTS>
Due to malfunction of sensor part of remote controller(IC3), it may does not work properly. In this case, take the following corrective countermeasure.
(Corrected set is dotted at the right side of serial No.)
<COUNTERMEASURE>
Due to the following corrective countermeasure, it prevents from the fault of sensor part by surge voltage.
1.Replace IC3 from GP1U281Y to SBX1981− 72P.
2.Add JW305 following the drawing(land exists).
3.Back solder ZENER,UZ6.8BSC following the drawing. Glue(KE− 3490) on the parts.
4.Put the dot mark at the right side of serial No. after countermeasure.
Circuit diagram | IC3 |
|
SBX1981− 72P | ||
1 | 2 | 3 |
JW305 |
|
|
IC1 36PIN
5V
ZENER6.8V
Pattern diagram MAIN PWB(Pattern side)
IC301 IC1
T602
Countermeasure
Circuit
countermeasure circuit
3
R1
2
Replace
SBX1981− 72P
IC3 |
1
Add JW305
Back soldering and apply glue to the ZENER 6.8V
| Serial No. matched to production |
|
|
|
|
|
|
| ||||||||
|
| S∗∗∗∗ | 16∗∗∗∗∗∼ |
| (All model except following suffixed model) |
|
| |||||||||
|
| S∗∗∗∗ | 15∗∗∗∗∗∼ | − | (TV C148 SHRJ4C,SHRJLRC,SHJRC ) |
|
| |||||||||
|
| S∗∗∗∗ | 14∗∗∗∗∗∼ | − | (TV C148 SHRJL1C,SHRJ1C,SHJLRC) |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Ref. |
| Parts Code |
|
| Description |
|
| Remarks | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| − |
| 87− A40− | 754− | 080 |
| ZENER,UZ6.8BSC |
| − |
| |||||
| IC3 |
| 87− A91− | 538− | 010 |
| RCR UNIT,SBX1981− | 72P |
| − |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||||
G |
| R | Code No |
|
| Access Code |
| Modified Ser. No. |
| Parts Schedule | ||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
− |
| − |
| − |
|
| − |
|
| mentioned in the above sentence | − | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|