1/1
Service Technical Information
| MODEL NO. | SUFFIX |
|
|
|
| TV− C1300 / S1311 / S2011 / CN140 | U |
|
|
|
| TV− AN145 / AS145 / AS205 / AS215 / CN140 | NH |
|
|
|
|
|
|
|
|
|
| SUBJECT |
|
|
|
|
| Power off |
|
| REF No :G − A1 − 053− E0 | |
|
|
|
| DATE :20. SEP. 2001 | |
|
|
|
| ||
|
|
|
|
|
|
<CONTENTS>
Power may off automatically due to the malfunction of 12 PIN (EXT terminal) of IC 1(micro processor)
In this case, please take the following corrective countermeasure.
<COUNTERMEASURE>
Micro processor may occur malfunction due to the noise of EXT terminal.
To prevent malfunction, attach the condenser 0.01∝ F parallel to D4 on the reverse side.
Circuit diagram | 5V | IC1 | |
|
| ||
I2C BUS | R40 | R35 | |
12 EXT | |||
INPUT CONNECTOR | |||
4PIN | Add |
| |
| D4 | ||
| 0.01∝ F |
Pattern diagram |
|
|
|
| Main C.B |
|
|
FRONT | counter measure | REAR |
|
| circuit | Expansion figure | |
|
| ||
| I C1 |
|
|
| I C301 | D4 | 0.01∝ F |
|
| ||
| IC1 | 12 | |
|
| ||
∗ Be sure with glue after attaching the condenser. |
|
| Ref. | Parts Code | Description |
|
| Remarks | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| − | 87− A11− 132− 080 | CAP,TC U 0.−01 50 K B |
| − | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
G |
| R |
| Code No. |
| Access Code | Modified Ser. No. |
| Parts Schedule | |
|
|
|
|
|
|
|
|
|
| |
− |
| − |
| − |
| − | − |
| − | |
|
|
|
|
|
|
|
|
|
|
|