ENFORCER
Setting the Timed Output:
When a channel is set to Timed Output, triggering the channel will activate the relay for a set period of time. Factory default is 1 second.
1. The time can be set from 1~60 seconds using the Timer switches on the top of the receiver.
2. Set switches according to the following chart.
NOTE: The time set via the DIP switches applies to all channels programmed for Timed Output.
Sec. | SW1 | SW2 | SW3 |
|
|
| Top of unit |
1* | On | Off | Off |
|
|
| |
|
|
|
| ||||
2 | Off | On | Off | Timer switches | |||
3 | Off | Off | On |
|
|
|
|
4 | On | Off | On |
|
|
|
|
|
|
|
| ||||
5 | Off | On | On |
|
|
|
|
|
|
|
| ||||
10 | On | On | Off |
|
|
|
|
30 | Off | Off | Off | SW1 SW2 SW3 | |||
60 | On | On | On |
|
|
|
|
*Default setting
Setting the Auxiliary Relay:
Each channel may be individually set to activate a separately timed 12VDC output programmable from 1 second to 10 minutes. The auxiliary relay provides up to 3A@12VDC*.
1.Connect the auxiliary device to the auxiliary relay. The two auxiliary relay terminals are the
2.Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch (SW8), located on the PCB as shown in the diagram below.
3.If the switch is in the ON position, triggering the
corresponding channel will activate the auxiliary relay.
4. If the switch is in the OFF position, triggering the corresponding channel will not activate the auxiliary relay.
Setting Auxiliary Relay Timer:
1.Output time can be adjusted from 1 second to 10 minutes using the auxiliary relay output time potentiometer.
2.Turning the potentiometer clockwise will increase the output time.
3.Turning the potentiometer counterclockwise will decrease the output time. Auxiliary relay time potentiometer
PCB |
Use the DIP switch to select the channel. Default is Channel 1 ON.
Terminal Block Auxiliary relay terminals
6 |