ENFORCER
Programming Each Channel Output:
1. Each channel output can be separately programmed for one of four different modes: Timed Output: When the channel receives a signal, the relay will turn ON for 1~60 seconds,
depending on the output time set.
Note: The timer, once set, is the same length for all outputs programmed for Timed Output. (See page 6 for timer programming.)
Toggle Output: When the channel receives a signal, the relay will turn ON and remain activated until a second signal is received.
Latch Output: When the channel receives a signal, the relay will turn ON. Turn the relay OFF by pressing that channel’s programming button on the Central Receiver unit.
Validity Output: When the channel receives a signal, the relay will turn ON for as long as a signal is being received.
2.To enter programming mode, press the button marked Mode on the top of the unit. Each channel’s red LED will flash a number of times to show the current output mode that it is in:
# of Flashes | Output Mode |
1 | Timed Output |
2 | Toggle Output |
# of Flashes | Output Mode |
3 | Latch Output |
4 | Validity Output |
3.To change modes, press the desired channel’s transmitter programming button. Each press moves to the next mode in the sequence shown in the diagram below. After changing modes, count the number of times the channel LED flashes to verify the channel is in the correct mode.
4.When finished, press Mode again to end programming.
Example 1: If the present mode is Timed Output, and the desired mode is Latch Output, press the channel’s programming button 2 times.
Example 2: If the present mode is Validity Output and the desired mode is Latch Output, press the channel’s programming button 3 times.
Programming Button Functions (Per Channel)
Timed Output |
|
|
| Latch Output |
(1 flash) |
|
|
| (3 flashes) |
Learn mode | Press and hold the button for 3 seconds or more to enter Learn mode. |
Clear memory | Press and hold the button for 3 seconds or more. When LED starts flashing, press |
| and hold again for 3 seconds to delete all learned codes. LED will flash twice. |
Reset Latch Output | If channel is set to Latch Output, press to turn relay off after it has been triggered. |
Memory display | Press momentarily. The Channel LED will flash a number of times corresponding to |
| the number of codes stored. |
LED Indicator Functions (Per Channel)
Steady ON | Receiving signal from transmitter OR indicates code has already been learned |
| during code learning. |
Fast flash | In either code learning OR memory display OR channel output programming mode. |
One flash | A transmitter’s code was learned OR channel relay is in Timed output mode. |
Two flashes | All learned codes were deleted OR channel relay is in Toggle output mode. |
Three flashes | Channel relay is in Latch output mode. |
Four flashes | Channel relay is in Validity output mode. |
0~15 flashes | During normal operation, press the programming button to display the number of |
| codes stored. 1 flash = 1 code stored. |
5 |