DEH-2130R,2100R
(4) Display of Operational Status (CPOINT) during Setup
Status No. | Contents |
|
| Protective action |
01 | Carriage move to home position started. | None | ||
02 | Carriage is moving toward inner diameter. | Specified 10 seconds has been passed or failure | ||
|
|
|
| on home switch. |
03 | Carriage is moving toward outer diameter. | Specified 10 seconds has been passed or failure | ||
|
|
|
| on home switch. |
05 | Carriage outer diameter feed (1 second) in progress. | None | ||
11 | Setup started. |
|
| None |
12 | Spindle rotation and focus search started. | None | ||
13 | Waiting for focus close (XSI= Low). | Specified focus search time has been passed. | ||
14 | Waiting for focus close (FOK= High). (After AGC) | Specified focus search time has been passed. | ||
15 | Waiting for focus close (FOK= High). (Before AGC) | Specified focus search time has been passed. | ||
16 | Rough AGC in progress. |
| Off focus. | |
17 | Setup (1/2) before T balance adjustment is started. | Off focus. | ||
18 | Setup (2/2) before T balance adjustment is started. | Off focus. | ||
24 | T balance adjustment (1/2). |
| Off focus. | |
25 | T balance adjustment (2/2). |
| Off focus. | |
26 | Standing by after spindle rough servo is over. | Off focus. | ||
27 | Setup before RF AGC (first) is started. | Off focus. | ||
28 | RF AGC (first) in progress. |
| Off focus. | |
29 | Setup before RF AGC (second) is started. | Off focus. | ||
30 | RF AGC (second) in progress. | Off focus. | ||
31 | Tracking close in progress. |
| Off focus. | |
32 | Standing by after tracking is closed. | Off focus. | ||
33 | Focus AGC started. |
| Off focus. | |
34 | Focus AGC in progress. Tracking AGC started. | Off focus. | ||
35 | Tracking AGC in progress. |
| Off focus. | |
| Spindle processes applicable servo. |
| ||
36 | Check of MIRR and LOCK pin. RF AGC in progress. | Off focus. Spindle not locked. | ||
| CRG close in progress. Check of | |||
(5) Display Examples |
|
|
| |
1) During Setup (When status no. = 11) |
|
| ||
| TRK No. | MIN. | SEC. |
|
| 11 | 11' | 11" |
|
2)During Operation (TOC read, TRK search, Play, FF and REV) The same as in the normal mode.
3)When a Protection Error Occurred
Switch to the following displays (A) and (B) using the [BAND] switch:
(A) Error occurrence timing display in absolute time.
An example: Error occurred in 12th tune at 34'56" in absolute time.
TRK No. | MIN. | SEC. |
12 | 34' | 56" |
(B) Error No. display
An example: Error #40 (Off focus is detected)
ERROR-40
47